Development of a system for testing full-size CMS LGAD sensors
Kyungmin Lee, Hoyong Jeong, Junho Kim, Seokhyeon Lee, Jaebak Kim, Jae Hyeok Yoo
Key points
From the paper's conclusion- We present a modular probe card system for automated electrical characterization of pixelated LGAD sensors, consisting of a probe card, a switching board, precision measurement instruments, and control software.
Abstract
Low-Gain Avalanche Diode (LGAD) sensors, offering timing resolutions of the order of tens of picoseconds, are being widely adopted in particle physics experiments and related applications. As these applications scale to large numbers of sensors with varying pixel geometries, conventional manual characterization techniques become inadequate for large-scale quality control. We present a modular probe card system for automated electrical characterization of pixelated LGAD sensors, consisting of a probe card, a switching board, precision measurement instruments, and control software. The system supports flexible pixel selection and measurement. Its performance is demonstrated through current-voltage (I-V) and capacitance-voltage (C-V) measurements of a 16 × 16 LGAD array. A rapid row-wise I-V scan of the full array is completed in approximately 20 minutes, while a pixel-by-pixel I-V scan from 0 to 300 V with a 1 V step requires about 340 minutes. The switching matrix introduces less than 1 nA of leakage current even in a conservative worst-case configuration, remaining small compared with the leakage current of the sensor tested in this work. The modular architecture and automation capability make the system a practical and scalable solution for large-scale LGAD sensor quality control and distributed testing environments.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Quality Control for the LGAD sensors of the ATLAS High Granularity Timing DetectorarXiv · 2026
- A Double Sided LGAD-Based Detector Providing Timing, Position, and Track Angle InformationarXiv · 2026
- Timing resolution from beam tests on thin LGADs down to 16.6 psNuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · 2026
- Characterization of BNLs 20 and 30 micrometer thick LGADs for the Electron Ion ColliderarXiv · 2026
- Ultra-Fast 4H-SiC AC-LGAD for 4D Tracking ApplicationsarXiv · 2026
- Developing the Readout Electronics for a Custom 64 × 64 SPAD Array: From Single-Board Prototyping to FPGA Implementation Toward Stellar Intensity Interferometry.Sensors (Basel, Switzerland) · 2026