Quality Control for the LGAD sensors of the ATLAS High Granularity Timing Detector
K. Ma, W. Sun, M. Ait Tamlihat, H. M. Alfanda, N. Atanov, O. Atanova, I. Azzouzi, J. Barreiro Guimar\~aes Da Costa,
Key points
From the paper's conclusion- This paper describes the Quality Control (QC) required for full-size (15 $\times$ 15 array) sensors, including leakage-current and breakdown measurements performed on all sensors at the vendor sites, as well as more detailed electrical characterizations at the participating ATLAS-HGTD institutes.
Abstract
The High Granularity Timing Detector (HGTD) currently in the production phase will mainly mitigate the pile-up effect in the ATLAS forward region and serve for bunch-by-bunch luminosity measurements in the high-luminosity (HL) phase of the Large Hadron Collider (LHC). The HGTD utilizes Low Gain Avalanche Detector (LGAD) technology, covering the pseudorapidity range between 2.4 and 4.0, and provides high-precision timing information to distinguish collisions occurring close in space but well-separated in time. A pre-production batch of 8-inch silicon wafers was fabricated and a systematic quality control test campaign was carried out. This paper describes the Quality Control (QC) required for full-size (15 $\times$ 15 array) sensors, including leakage-current and breakdown measurements performed on all sensors at the vendor sites, as well as more detailed electrical characterizations at the participating ATLAS-HGTD institutes. In addition, the electrical characterization of full-size sensors after irradiation is reported.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Development of a system for testing full-size CMS LGAD sensorsJournal of Instrumentation · 2026
- A Double Sided LGAD-Based Detector Providing Timing, Position, and Track Angle InformationarXiv · 2026
- Characterization of BNLs 20 and 30 micrometer thick LGADs for the Electron Ion ColliderarXiv · 2026
- Timing resolution from beam tests on thin LGADs down to 16.6 psNuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · 2026
- Evaluation of Performance of the p-stop fabrication process variations in ATLAS18 strip sensors, Pre- and Post-IrradiationarXiv · 2026
- Comparison of Silvaco and Synopsys TCAD predictions including the Perugia radiation damage model in silicon pixel detectors for the HL-LHCJournal of Instrumentation · 2026