Journal of Physics: Conference Series

Finite Element Model to Determine the Fire Resistance of Protected and Unprotected Timber Columns

Paulo A. G. Piloto

Key points

From the paper's conclusion
  • Overall, the proposed finite element model offers a robust method for fire-safe design and assessment of timber columns, both with and without passive protection material (gypsum).

Abstract

This paper presents a validated three-dimensional finite element model for predicting the fire resistance of protected and unprotected glulam timber columns exposed to ISO 834 fire conditions. The model includes temperature-dependent, isotropic thermal properties and orthotropic mechanical properties, charring progression, geometric and material nonlinearities, and thermomechanical coupling, and it is validated against experimental fire tests on a representative specimen. Good agreement is obtained for temperature evolution, axial displacement, and fire resistance time, supporting the model’s reliability for simulating the structural behaviour of timber columns under fire exposure. A parametric study examines the influence of load level and gypsum protection thickness on fire performance. The results show that gypsum plasterboard significantly delays heating and charring, thereby increasing fire resistance, whereas higher load ratios reduce the column’s fire endurance. The study also compares the finite element results with simplified design methods from different generations of EN1995-1-2, showing that the newer formulation yields closer predictions but still tends to overestimate fire resistance compared with the finite element model. Overall, the proposed finite element model offers a robust method for fire-safe design and assessment of timber columns, both with and without passive protection material (gypsum).

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers