Assessment of primary frequency regulation capability and optimization of guide vane closing law for pumped storage power units
Zhongwei He, Fei Zhang, Chengjun Li, Lei Deng
Key points
From the paper's conclusion- The results show that when the unit operates at an 8% overload of its rated active power, the minimum pressure at the draft tube inlet and the maximum unit speed both meet the control requirements for regulation guarantee calculations.
Abstract
The primary frequency regulation capability of pumped storage plants, especially their short-term capacity-increase capacity, is critical for power grid security. However, the original guide vane closing laws in some stations, while supporting power output increase, may induce risks such as unit speed oscillations and transient pressure exceeding the threshold. This study takes Hydraulic Unit 1 of the Jinyun Pumped Storage Plant (adopting a single penstock for two units) as the research object. A transient process calculation model based on the one-dimensional method of characteristics is established in this study. Four typical load rejection transient processes are selected to systematically evaluate the dynamic characteristics of the unit during primary frequency regulation with increased output. Subsequently, the guide vane closing law is further optimized to ensure the stable operation of both the unit and the power grid while providing maximum active power support to the grid. The results show that when the unit operates at an 8% overload of its rated active power, the minimum pressure at the draft tube inlet and the maximum unit speed both meet the control requirements for regulation guarantee calculations. However, during some transient processes, the maximum pressure at the spiral case inlet slightly exceeds the control limit, posing a potential threat to the penstock system. Accordingly, the breakpoint opening of the original piecewise linear guide vane closing law is adjusted, ensuring that the maximum spiral case pressure, the unit speed rise ratio, and the minimum draft tube inlet pressure all satisfy the control requirements. Furthermore, the influence law of the breakpoint opening on the aforementioned parameters under different load rejection transients is summarized. The research findings help to ensure the safety of transient processes while fully utilizing the unit’s overload capability, providing a reference for the operational optimization of similar pumped storage plants.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Numerical Investigation of Internal Flow Characteristics in a Variable-Speed Pumped Storage Power Plant During Load Rejection with Guide Vane Closing FailureSymmetry · 2026
- Research on start-up transition process of high-head pumped storage unitsFrontiers in Mechanical Engineering · 2026
- Research on Automatic Power Generation Control and Primary Frequency Regulation Parameter Characteristics of Hydropower UnitsWater · 2025
- Internal Flow Characteristics of a Variable-Speed Pump-Turbine Unit During Combined Load-Variation and Load-Rejection TransientsSymmetry · 2026
- Mitigating Low Pressure in Draft Tubes of Pumped-Storage Units by Installing Tailwater Connection Pipes Under Successive Load Rejection Conditions: Mechanism and Effectiveness AnalysisWater · 2026
- Transient hydrodynamic instability during the rapid closing process of the guide vanes of pump turbines under power generation conditionsProceedings of the Institution of Mechanical Engineers Part C Journal of Mechanical Engineering Science · 2026