Journal of Physics: Conference Series

Assessment of primary frequency regulation capability and optimization of guide vane closing law for pumped storage power units

Zhongwei He, Fei Zhang, Chengjun Li, Lei Deng

Key points

From the paper's conclusion
  • The results show that when the unit operates at an 8% overload of its rated active power, the minimum pressure at the draft tube inlet and the maximum unit speed both meet the control requirements for regulation guarantee calculations.

Abstract

The primary frequency regulation capability of pumped storage plants, especially their short-term capacity-increase capacity, is critical for power grid security. However, the original guide vane closing laws in some stations, while supporting power output increase, may induce risks such as unit speed oscillations and transient pressure exceeding the threshold. This study takes Hydraulic Unit 1 of the Jinyun Pumped Storage Plant (adopting a single penstock for two units) as the research object. A transient process calculation model based on the one-dimensional method of characteristics is established in this study. Four typical load rejection transient processes are selected to systematically evaluate the dynamic characteristics of the unit during primary frequency regulation with increased output. Subsequently, the guide vane closing law is further optimized to ensure the stable operation of both the unit and the power grid while providing maximum active power support to the grid. The results show that when the unit operates at an 8% overload of its rated active power, the minimum pressure at the draft tube inlet and the maximum unit speed both meet the control requirements for regulation guarantee calculations. However, during some transient processes, the maximum pressure at the spiral case inlet slightly exceeds the control limit, posing a potential threat to the penstock system. Accordingly, the breakpoint opening of the original piecewise linear guide vane closing law is adjusted, ensuring that the maximum spiral case pressure, the unit speed rise ratio, and the minimum draft tube inlet pressure all satisfy the control requirements. Furthermore, the influence law of the breakpoint opening on the aforementioned parameters under different load rejection transients is summarized. The research findings help to ensure the safety of transient processes while fully utilizing the unit’s overload capability, providing a reference for the operational optimization of similar pumped storage plants.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Assessment of primary frequency regulation capability and optimization of guide vane closing law for pumped storage power units — Science Skim