Research on corrosion detection criteria for tower grounding grids based on corrosion characteristics and magnetic field response
Zinan Zheng, Peng Zhang, Weibin Ou, Weihua Chen, Yao Tong
Key points
From the paper's conclusion- As soil pore saturation increases from 20% to 70%, corner corrosion current density rises markedly.
Abstract
This paper develops a corrosion simulation model for tower grounding grids to analyze corrosion mechanisms, corrosion-prone regions, material differences, and the electromagnetic detection basis. Chemical, electrochemical, stress, and microbiologically influenced corrosion in soil are examined, showing that corrosion reduces conductor cross-section, increases resistance, and changes current distribution. A full-scale finite-element model is built, with soil pore saturation used to describe changes in soil resistivity and oxygen diffusion. Corrosion rates under different locations, materials, and damage conditions are calculated, and the applicability of electromagnetic detection is discussed based on surface magnetic-field variations. Results show that corrosion is more severe at grid corners and extension ends, while frame corrosion is higher at both ends and lower in the middle. As soil pore saturation increases from 20% to 70%, corner corrosion current density rises markedly. Galvanized steel and low-carbon steel are more sensitive to soil moisture, whereas flexible graphite and copper-clad steel have better corrosion resistance. This study provides guidance for corrosion-state identification, detection-path design, and grounding-grid maintenance.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Simulation research on corrosion state detection of tower grounding grids based on magnetic field responseJournal of Physics: Conference Series · 2026
- Aplicación de sondeos eléctricos como ensayos no destructivos para la evaluación de corrosión en elementos de aceroConcienciaDigital · 2026
- Analysis of grounding characteristics of single-direction extended auxiliary grounding grids for transmission towersJournal of Physics: Conference Series · 2026
- A review of recent developments on the localized corrosion of mild steel used in the oil and gas industryDiscover Materials · 2025
- Spatial Localization and Geometric Scaling of Galvanic Corrosion Between 42CrMo Steel and 410 Stainless Steel in Low-Conductivity Yangtze River FreshwaterCoatings · 2026
- Corrosion Monitoring of Metal Components in the Beishan Underground LaboratoryMaterials and Corrosion · 2026