Optimizing radiobiological effects of119Sb targeted radionuclide therapy via DNA incorporation: a Monte Carlo simulation study.
Andrew Vincent Zwaniga, Eric Da Silva, James L Gräfe
Department of Physics, Toronto Metropolitan University, 350 Victoria St, Toronto, Ontario, M5B 2K3, Canada.
Key points
From the paper's conclusion- Objective: We investigate the hypothesis that the radiobiological effects of 119 Sb make it the most potent Auger electron-emitting radionuclide for targeted radionuclide therapy (TRT) of micrometastases.
Abstract
We investigate the hypothesis that the radiobiological effects of119Sb make it the most potent Auger electron-emitting radionuclide for targeted radionuclide therapy (TRT) of micrometastases. The objectives of this study were to evaluate radiobiological effects of119Sb decays in close proximity to DNA, to examine the sensitivity of the effects to the Auger electron spectrum model, and to compare these effects among contemporary Auger electron-emitters to determine if the effects of119Sb are the largest. Approach: TOPAS Monte Carlo was used to calculate dose-mean lineal energy, DNA strand breaks, and G-values within 10 nm of a simplified DNA double helix. Decay spectra were obtained from MIRD RADTABS07 and Geant4 Atomic Relaxation. The microdosimetric kinetic (MK) model was used to estimate the RBE relative to 200 kVp x-rays radiation with the assumption of equal, constant119Sb dose rate. Quantitative comparisons were made with103mRh,103Pd,111In,123I,125I,165Er, and197Hg. Main Results: Dose-mean lineal energy and DNA damage are maximized when119Sb is incorporated into DNA. In this highly idealized geometry, the dose-mean lineal energy is (189.37±0.06) keV/μm and the RBE is 3.2±0.6 ((σstat<0.01%)) which is indistinguishable from the competing radionuclides due to parameter uncertainties. Within 10 nm the RBE decreases by a factor of two. Abridging the Auger spectrum significantly underestimates these effects. DNA incorporation maximizes strand breaks at 2.2119±0.0016 (stat.) SSBs and 0.3207±0.0007 (stat.) DSBs per decay, which decrease by two orders of magnitude at 10 nm. Conversely, G-values of free radicals in the DNA volume increase with distance by an order of magnitude.119Sb yields relatively less DNA damage, and larger free radical yields than111In,123I and125I but smaller yields than103mRh,103Pd,165Er and197Hg. Significance: Localization of119Sb to the DNA double helix is critical to optimize radiobiological effects. Researchers developing119Sb TRT should therefore focus on solutions to achieve incorporation into DNA. In this highly-idealized geometry, RBE values are the same among the competitor radionuclides; however, more research is needed to account for exponential decay, clearance, and DNA repair before the RBE results can be interpreted categorically. Limitations in the strand break calculations point to the need to account for complex DNA damage and sublethal damage repair which may be more sensitive to the higher yield of119Sb Auger electrons.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Radiobiological effectiveness of varying Tb-161 and Lu-177 distributions in the nuclei of targeted cells.Journal of radiation research · 2026
- From voxel S-values to DNA damage: Multiscale simulation of β- emitters with Geant4 and Geant4-DNA.Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2026
- Contemporary opportunities and potential of Auger electron-emitting theranosticsTheranostics · 2026
- Monte Carlo study of 6Li ion irradiation and 186Re-induced DNA damage.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- Comparative analysis of early DNA damage in three human cell models exposed to Lu-177 and Tb-161 radionuclides using Geant4-DNA simulation toolkit.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- Biodistribution and dosimetry of free118Te, anin vivogenerator of the positron emitter118Sb for long-term positron emission tomography.Physics in medicine and biology · 2026