Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)

From voxel S-values to DNA damage: Multiscale simulation of β- emitters with Geant4 and Geant4-DNA.

Aurora Leso, Alberto Arzenton, Giulia S Valli, Davide Serafini, Antonietta Donzella, Marcello Lunardon, Lisa Zangrando, Emilio Mariotti,

Department of Physics and Earth Sciences, University of Ferrara, Ferrara, Italy; INFN - Legnaro National Laboratories, Legnaro (PD), Italy. · Department of Physics and Astronomy, University of Padua, Padua, Italy; INFN - Padua Division, Padua, Italy. Electronic address: alberto.arzenton@pd.infn.it.

Computational

Key points

From the paper's conclusion
  • The innovative radionuclides 111Ag, 161Tb, and 47Sc behave very similarly to radionuclides already applied in nuclear medicine. For this reason, the preclinical development of radiopharmaceuticals labeled with these radioactive agents should be kept under observation in the near future.

Abstract

PURPOSE: The present study investigates dosimetric profiles and radiation-induced DNA damage for several therapeutic β- emitters, with particular emphasis on 111Ag, 47Sc, and 161Tb in the framework of the ISOLPHARM project. METHODS: Monte Carlo simulations are performed using the Geant4 toolkit and its extension Geant4-DNA. Macroscopic dosimetry is studied in voxelized and spherical geometries. Concerning the DNA damage evaluation, the same DNA geometries, physicochemical stage, and damage scoring criteria as those in the literature pertaining to the Geant4-DNA project are adopted to ensure direct comparability. Electron spectra from 47Sc, 90Y, 111Ag, 131I, 153Sm, 161Tb, 177Lu, and 186Re are sampled, taking into account both β- and Auger radiation. RESULTS: A database including voxel S-values and dose point kernels for each medical β- emitter has been computed. DNA damage data for the same nuclides, in terms of single- and double-strand breaks, have been simulated with the Geant4-DNA libraries. Results are similar for almost all radionuclides, probably because of the higher weight of indirect DNA damage rather than direct. CONCLUSIONS: The innovative radionuclides 111Ag, 161Tb, and 47Sc behave very similarly to radionuclides already applied in nuclear medicine. For this reason, the preclinical development of radiopharmaceuticals labeled with these radioactive agents should be kept under observation in the near future.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.