Comparative analysis of early DNA damage in three human cell models exposed to Lu-177 and Tb-161 radionuclides using Geant4-DNA simulation toolkit.
Đorđe D Nešković, Minja Vuković, Otilija Keta, Konstantinos Chatzipapas, Hoang Ngoc Tran, Sebastien Incerti, Miloš Đorđević
University of Belgrade - School of Electrical Engineering, Bulevar kralja Aleksandra 73, Belgrade, 11120, Serbia; Vinča Institute of Nuclear Sciences - National Institute of the Republic of Serbia, University of Belgrade, Mike Petrovića Alasa 12-14, Belgrade, 11351, Serbia. · University of Belgrade - School of Electrical Engineering, Bulevar kralja Aleksandra 73, Belgrade, 11120, Serbia; Vinča Institute of Nuclear Sciences - National Institute of the Republic of Serbia, University of Belgrade, Mike Petrovića Alasa 12-14, Belgrade, 11351, Serbia. Electronic address: minja.vukovic@vin.bg.ac.rs.
Key points
From the paper's conclusion- The higher DSB yield per unit absorbed dose of Tb-161, associated with its pronounced low-energy Auger and conversion electrons, could depend on intranuclear delivery and the nuclear morphology of targeted cells, highlighting the potential relevance of Tb-161 for radionuclide therapy.
Abstract
PURPOSE: The investigation of novel radionuclides is crucial for advancing targeted radionuclide therapy. A challenge lies in optimizing their therapeutic efficacy, governed by radiation emission profiles and intracellular localization. The Geant4-DNA toolkit was used to perform a Monte Carlo simulation study of early Deoxyribonucleic Acid (DNA) damage induced by radionuclides. METHOD: This study simulates and compares DNA strand damage, including single-strand breaks (SSBs) and double-strand breaks (DSBs) induced by Lu-177 and Tb-161 in three human cell models: "human cell", "PANC-1", and "HTB177". We investigated uniform radionuclide distribution, comparing radionuclide decays distributed within the nucleus volume with those localized on the nucleus surface for each cell model. RESULTS: Our results demonstrate that Tb-161 consistently produces higher DSB yields than Lu-177 across all simulated conditions, with a DSB ratio (Tb-161/Lu-177) of approximately 1.3 for the "human cell", 1.4 for "PANC-1", and 1.2 for "HTB177" nuclei with uniform volumetric distribution. When radionuclides were localized to the nucleus surface, this ratio increased to approximately 1.6 and 1.5 for the "human cell" and "PANC-1" nuclei, respectively, while it was slightly attenuated to approximately 1.1 for "HTB177". This geometry-dependent behavior reflects the interplay between the short range of Tb-161 Auger and conversion electrons and the size and chromatin density of the targeted cell nucleus. CONCLUSION: The higher DSB yield per unit absorbed dose of Tb-161, associated with its pronounced low-energy Auger and conversion electrons, could depend on intranuclear delivery and the nuclear morphology of targeted cells, highlighting the potential relevance of Tb-161 for radionuclide therapy.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Radiobiological effectiveness of varying Tb-161 and Lu-177 distributions in the nuclei of targeted cells.Journal of radiation research · 2026
- Impact of uniform and Gaussian intracellular activity distribution on DNA damage: a Geant4-DNA study of Auger electron-emitting radionuclides in V79 cells.Physics in medicine and biology · 2026
- From voxel S-values to DNA damage: Multiscale simulation of β- emitters with Geant4 and Geant4-DNA.Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2026
- Optimizing radiobiological effects of119Sb targeted radionuclide therapy via DNA incorporation: a Monte Carlo simulation study.Physics in medicine and biology · 2026
- Monte Carlo study of 6Li ion irradiation and 186Re-induced DNA damage.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- Coupling target and radioactive emitter matters: a sub-tissue dosimetric study to identify optimal strategiesEJNMMI Physics · 2026