Automated carotid artery atherosclerotic inflammation segmentation in PET using MSR-Net.
Ran Li, Abhinav K Jha, Jie Zheng, Richard Laforest, Yongjian Liu, Mohamed Zayed, Tyler J Fraum, Barry A Siegel,
Mallinckrodt Institute of Radiology, Washington University in St. Louis, 4525 Scott Ave, St. Louis, 63110, United States.
Key points
From the paper's conclusion- Overall ENRMSE
was 0.24 versus 0.59, 0.68, and 0.59 for the three DL baselines and 0.57 for iterative Yang.
In seven patients, corrected SUV showed a positive association with MR-derived
lipid-rich/necrotic core with hemorrhage.
Significance.
Abstract
Abstract Objective. To develop an automated method for segmentation and uptake quantification of carotid atherosclerotic inflammation on 64Cu-CANF-comb PET while accounting for partial-volume and tissue-fraction effects. Approach. Synthetic carotid PET images with known fractional-volume ground truth were generated by combining MR-derived high-resolution activity maps with GATE Monte Carlo simulation incorporating major PET physical processes and matched to the Biograph mMR acquisition and reconstruction. A two-stage network first localized the carotid vessel wall from T1-weighted MR and then estimated voxel-wise inflammation fraction from masked PET. Both stages used a multiscale residual (MSR) convolutional backbone. Performance was compared with U-Net, Transformer U-Net, DUCK-Net, and iterative Yang partial-volume correction. Main results. In a two-alternative forced-choice study, five nuclear-medicine physicians identified real images with 54% accuracy (54/100; Wilson 95% CI 0.44-0.63; exact binomial p = 0.48). On 184 simulated test slices from five held-out patients, the proposed method achieved a weighted DSC of 0.79, compared with 0.73 for U-Net, 0.69 for Transformer U-Net, and 0.75 for DUCK-Net, with corresponding HD values of 1.85, 2.29, 2.32, and 2.23 voxels. Patient-cluster bootstrap comparisons favored the proposed method for DSC and HD against all three baselines (Holm-corrected p ≤ 0.031). Overall ENRMSE was 0.24 versus 0.59, 0.68, and 0.59 for the three DL baselines and 0.57 for iterative Yang. In seven patients, corrected SUV showed a positive association with MR-derived lipid-rich/necrotic core with hemorrhage. Significance. The proposed framework improved carotid PET segmentation and uptake quantification under simulated conditions. The patient analysis is preliminary and requires external validation with biological reference standards before clinical deployment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- DMNet-E: Enhanced dual-segmentation multi-decoder network strategy for advancing IVOCT plaque segmentation.Artificial intelligence in medicine · 2026
- MUSE-Net: a SegFormer-B2-based multi-expert ensemble for multicenter carotid plaque segmentation in ultrasound images.Medical & biological engineering & computing · 2026
- Atherosclerosis diagnosis from magnetic resonance images: an empirical approach to automate carotid vessel wall segmentation and feature-based prediction.Physical and engineering sciences in medicine · 2026
- EXPRESS: Diagnostic Accuracy of Noninvasive Translesional Pressure Ratio Based on Magnetic Resonance Imaging for Intracranial Atherosclerotic Stenosis: A Validation Study.Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism · 2026
- Automatic cerebral angiographic perfusion analysismedRxiv · 2026
- Automated Distinction of Intimal and Medial Intracranial Arterial Calcification from CT HeadarXiv · 2026