From the paper's conclusion- Manually processed perfusion comparisons included 165 external runs from 52 patients.
Abstract
Purpose: To automate anatomical localization for angiographic perfusion and evaluate agreement with manual processing between biplane projections in a held-out external cohort. Methods: Separate anteroposterior (AP) and lateral projection hemisphere and internal carotid artery (ICA) models used DeepLabv3+ with ResNet50 encoders. Development used patient-separated training, validation, and testing. External patients were excluded from fitting and model selection. Automated pipeline and manual-pipeline perfusion shared downstream calculations. Eligible acquisitions contained at least 7 seconds of data after bolus arrival. Segmentation metrics and Bland-Altman analyses evaluated mean transit time (MTT) and time to maximum of the residue function (Tmax). Results: External segmentation testing included 353 runs from 73 patients. Patient-mean hemisphere Dice was 0.959 (95% CI, 0.952-0.965) in AP and 0.965 (0.960-0.969) in lateral views while ICA Dice was 0.635 (0.617-0.650) and 0.558 (0.534-0.579). Manually processed perfusion comparisons included 165 external runs from 52 patients. Mean absolute differences (95% CI) were 0.39 (0.31-0.47) and 0.32 (0.25-0.40) seconds for AP and lateral MTT, and 0.23 (0.15-0.35) and 0.31 (0.17-0.51) seconds for Tmax. Among 220 external cohort biplane pairs from 61 patients, mean absolute differences were 0.48 seconds (95% CI, 0.42-0.53) for MTT and 0.53 seconds (0.35-0.75) for Tmax. Repeated-measures mean biases (95% CI) were -0.07 (-0.19 to 0.05) and 0.16 seconds (-0.08 to 0.40), with 95% limits of agreement of -1.38 to 1.24 and -2.65 to 2.97 seconds respectively. Conclusion: Our automated perfusion pipeline showed favorable agreement with manually processed results in the external validation cohort. Independently processed biplane views had small average bias.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Anatomy- and Time-Based Post-Processing with CT Perfusion-Derived Time-Vessel Maps to Reduce Incorrect Occlusion Detections in Late-Phase CT Angiography.Diagnostics (Basel, Switzerland) · 2026
- Dual-phase vessel wall MRI deep learning for identifying composite unstable intracranial aneurysm phenotypes: a multicenter studymedRxiv · 2026
- ArteryX: A Reliable End-To-End Toolbox for Standardized Intracranial Artery Feature Extraction From 3D TOF-MRA.Magnetic resonance in medicine · 2026
- TriAIF-RWKV: A Physiology-Guided Spatiotemporal Framework for Robust Arterial Input Function Selection in CT Perfusion Imaging.Entropy (Basel, Switzerland) · 2026
- Automated Segmentation of Intracranial Arteries on 4D Flow MRI for Hemodynamic QuantificationmedRxiv · 2026
- Structure-Aware OCTA Segmentation for OCTA-Derived Quantitative Analysis of Cerebral Microvascular Perfusion in Ischemic Stroke.Tomography (Ann Arbor, Mich.) · 2026