MUSE-Net: a SegFormer-B2-based multi-expert ensemble for multicenter carotid plaque segmentation in ultrasound images.
Ming Hao, Jun Huang, Jiajia Song, Mingming Chen, Chang Liu, Xiangting Song, Kailin Gong, Li Fan,
Changzhou First People's Hospital, the Third Affiliated Hospital of Soochow University, Juqian Street, Changzhou, Jiangsu, 213003, China. · the Second People's Hospital of Changzhou, the Third Affiliated Hospital of Nanjing Medical University, Yanling Middle Road, Changzhou, Jiangsu, 213004, China.
Key points
From the paper's conclusion- We propose MUSE-Net, a SegFormer-B2-based multi-expert ensemble.
Abstract
Accurate carotid atherosclerotic plaque segmentation in B-mode ultrasound is essential for quantitative vascular assessment, but multicenter variability in scanners, views, image quality, and annotation practice limits model robustness. We propose MUSE-Net, a SegFormer-B2-based multi-expert ensemble. Each expert contains a long-axis binary plaque branch and a short-axis three-class lumen/plaque branch. Each branch uses a MiT-B2 encoder and SegFormer all-MLP decoder. MUSE-Net combines five-fold expert training, long-axis test-time augmentation, probability-level aggregation, and connected-component refinement. On a four-center dataset, MUSE-Net achieved a mean Dice similarity coefficient of 0.834 and mean intersection-over-union of 0.748. Paired Wilcoxon testing showed significant case-wise gains over all baselines (win rate, 57.6-81.8%; all; rank-biserial effect size, 0.274-0.731). Component-wise ablation identified backbone capacity and five-expert aggregation as the principal contributors to performance. Center-wise and leave-one-center-out analyses indicated robustness under heterogeneous acquisition, but do not establish broad patient-level generalizability. Because strict patient-level separation could not be retrospectively verified for all historical centers, performance may be optimistically biased. The current evidence supports segmentation and pixel-based plaque-area quantification, which indicate that our MUSE-Net has the potential in clinical outcome prediction or routine deployment in the future.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- FSS-Net: frequency-spatial synergy network with wavelet attention for carotid artery ultrasound segmentationDisplays · 2026
- Mask R-CNN-based carotid plaque localization in ultrasound images.Journal of medical imaging (Bellingham, Wash.) · 2026
- A comparative study of the state-of-the-art artificial intelligence models for automated plaque measurement in a carotid ultrasound Japanese cohort.Cardiovascular diagnosis and therapy · 2026
- RTCMUNet: retinex-inspired feature modulation for breast ultrasound lesion segmentation.Physics in medicine and biology · 2026
- DMNet-E: Enhanced dual-segmentation multi-decoder network strategy for advancing IVOCT plaque segmentation.Artificial intelligence in medicine · 2026
- Atherosclerosis diagnosis from magnetic resonance images: an empirical approach to automate carotid vessel wall segmentation and feature-based prediction.Physical and engineering sciences in medicine · 2026