The effect of tumor subregions in the evaluation of electron absorbed fraction and S factor.
Christina Kotroumpelou, Ioanna Kyriakou, Sebastien Incerti, Dimitris Emfietzoglou
Medical Physics Lab, Department of Medicine, University of Ioannina, 45110, Ioannina, Greece. · University of Bordeaux, Centre National de La Recherche Scientifique, Laboratoire de Physique des Deux Infinis, Unité Mixte de Recherche 5797, F-33170, Gradignan, France.
Key points
From the paper's conclusion- The results show that the common assumption of uniform activity distribution in the tumor volume can lead to substantial deviations (27-87%) from more realistic distributions, whereby tumor subregions are considered.
Abstract
Absorbed fractions and S factors are essential inputs in MIRD-based dosimetry for radiopharmaceutical therapy (RPT). Their evaluation for six therapeutic β-emitting radionuclides (Y-90, I-131, Lu-177, Sr-89, Sm-153, and Re-186), as well as for monoenergetic electrons over the energy range of interest to RPT (1 keV - 4 MeV) is presented for intermediate-size tumors (∼mm), considering more realistic radionuclide distributions that explicitly account for oxygenated and necrotic tumor subregions. Calculations are performed using both the semi-analytic dose point kernel (DPK) approach and Monte Carlo (MC) simulations with the Geant4 toolkit. The results show that the common assumption of uniform activity distribution in the tumor volume can lead to substantial deviations (27-87%) from more realistic distributions, whereby tumor subregions are considered. The use of the mean β energy instead of the full emission spectrum introduces additional discrepancies, which become even more significant (up to 50-100%) in the examined cases. The comparison between the DPK-based calculations and the Geant4 simulations reveals differences up to 60%, primarily when the electron range is comparable to the characteristic dimensions of the tumor subregions. Although the choice of common cut-off energy parameters in the Geant4 simulations has a limited influence in the case of uniform activity distribution, it may introduce sizeable discrepancies (up to 23%) in the more realistic cases examined. The present findings underscore the importance of incorporating oxygenated and necrotic tumor subregions in the dosimetry of intermediate-size tumors along with appropriate modeling of electron transport.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Microdosimetry and biological effectiveness of 35 radionuclides for targeted tumor therapy: alpha, beta, and low-energy electron emitters.International journal of radiation biology · 2026
- Coupling target and radioactive emitter matters: a sub-tissue dosimetric study to identify optimal strategiesEJNMMI Physics · 2026
- Normal-Organ Absorbed Dose and Response Assessment in α-Particle Radiopharmaceutical Therapy.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2026
- Towards personalised dosimetry based prescription of therapeutic radiopharmaceuticals: an EURADOS positionEJNMMI Physics · 2026
- Clinical translation of targeted alpha therapy: safety, dosimetry, radiation protection, and regulatory considerations.Seminars in nuclear medicine · 2026
- Radiobiological effectiveness of varying Tb-161 and Lu-177 distributions in the nuclei of targeted cells.Journal of radiation research · 2026