Mechanism analysis and compensation method for tiltinduced error in chromatic confocal thickness measurement of transparent media
Xiali Liu, Yaohua Deng
Key points
From the paper's conclusion- The results show that stable dual-interface responses can still be maintained at small tilts, whereas beyond a critical tilt range the system exhibits rapid coupling loss and reduced peak separability.
Abstract
Chromatic confocal sensing provides a noncontact approach for thickness measurement of transparent media with multiple interfaces. In practice, however, unavoidable sample tilt causes simultaneous degradation of return-signal coupling and spectral response, which leads to significant thickness errors. In this work, the error formation pathway from tilt to spectral distortion and finally to thickness deviation is systematically investigated, and a compensation method is proposed. First, based on the weighted superposition of entrance-pupil energy contributions, the effects of tilt-induced off-axis return and off-axis dispersion-mapping variation on spectral peak position and profile stability are analyzed. A Zemax non-sequential ray tracing model is then established to quantify the evolution of the two-dimensional irradiance distribution, return power, and dual-interface spectral features under different tilt angles. The results show that stable dual-interface responses can still be maintained at small tilts, whereas beyond a critical tilt range the system exhibits rapid coupling loss and reduced peak separability. Experimental measurements using a CL3-MG70 probe and transparent quartz plates further confirm the simulation trends and show that the tilt-induced thickness error increases approximately in proportion to the sample thickness. On this basis, a unified magnification model is established for the investigated probe and quartz samples and applied to tilt-error compensation. Using the thickness deviation relative to the 0° condition as the evaluation metric, the proposed method reduces both the maximum drift and RMSE by more than 90%, demonstrating a substantial improvement in measurement stability. These results provide a practical reference for tilt error analysis and correction in chromatic confocal thickness measurement of rigid transparent plates.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Chromatic confocal color decoding of surface residual stress in optical components.Optics letters · 2026
- A Method for Eliminating Mixed Errors in Confocal Images by Integrating System Error Matrices with Low-Rank ApproximationPhotonics · 2026
- Total Corneal Aberration Measurements by Anterior Segment Optical Coherence Tomography and Scheimpflug-Based Imaging: A Narrative Review of Optical Principles and Sources of Inter-Device Discordance.Journal of clinical medicine · 2026
- Interferometry at the onset of total internal reflection.Optics letters · 2026
- Subaperture stitching measurement for optical components based on the trust region reflective algorithm.Optics express · 2026
- Optimizing Slit-Lamp Specular Reflection for Corneal Endothelial Observation: A Practical Guide to Clinical Applications.Clinical ophthalmology (Auckland, N.Z.) · 2026