A Method for Eliminating Mixed Errors in Confocal Images by Integrating System Error Matrices with Low-Rank Approximation
Huanhuan Hu, Dingrong Yi, Youbo Hu, Caihong Huang
Key points
From the paper's conclusion- Therefore, this method enriches the field of confocal image surface measurement and topography restoration with noise elimination in both theory and practice.
Abstract
In view of the difficulty in simultaneously eliminating multiple systematic errors and random errors in parallel bilateral chromatic dispersion differential confocal images, this paper proposes a hybrid error simultaneous removal method that integrates its prior systematic error matrix and low-rank approximation of random errors. Firstly, the causes of multiplicative systematic errors such as uneven illumination, different reflectivity, and stage tilt in the parallel bilateral chromatic dispersion differential confocal microscopy (PBCDDCM) measurement system are analyzed, and the systematic error matrix is experimentally measured. Then, the causes of random errors such as dead pixels and Gaussian noise in confocal images are analyzed, and the prior knowledge of the low-rank matrix recovery model is utilized to simultaneously eliminate multiple types of random noise. By integrating the systematic error matrix into the low-rank matrix recovery model, designing a low-rank approximation function, and solving the low-rank matrix recovery model using the alternating direction method of multipliers, a confocal image with eliminated systematic and random errors is obtained. This method is applied to eliminate mixed errors in confocal images of standard step samples and industrial sample gold fingers, and their surface topography is measured and Poisson surface modeling is performed. Experiments show that for a standard step sample with a height of 15 μm, the average height value of the measured step surface before correction is 15.14 μm, with a relative error of 1.06%. After correction, the average height value of the measured step surface is 14.99 μm, with a relative error of 0.07%. The surface topography of the gold finger is restored, and its imaging quality is significantly improved. The average height value of the steps obtained from multiple measurements of the gold finger is 19.54 μm, which has a relative deviation of 2.51% compared to the height measurement result of 19.06 μm obtained at the same position on an Olympus laser microscope. Therefore, this method enriches the field of confocal image surface measurement and topography restoration with noise elimination in both theory and practice.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Chromatic confocal color decoding of surface residual stress in optical components.Optics letters · 2026
- High‐Fidelity, Adaptive Label‐Free Imaging via Color‐Multiplexing With Analytical Aberration EstimationLaser & Photonics Reviews · 2026
- Universal Drift Correction for Multidimensional Scanning MicroscopyarXiv · 2026
- Measurement Error Models Enable Accurate Correlation of Nanoscale Properties and Structures.ACS nano · 2026
- Representation Bias, Correction Transfer, and Resolution Sensitivity in Three-Dimensional Mitochondrial MorphometryarXiv · 2026
- Advanced Algorithms of Mitigating Undermatched Systematic Error in DICExperimental Mechanics · 2025