Robust PPG-Exclusive Heart Rate Estimation During Maximal Exercise Using Population-Based Priors
Elisabetta De Giovanni, I\~nigo Urteaga, Matteo Croci, Tomas Teijeiro
Key points
From the paper's conclusion- These results show that physiological priors and DTW-based alignment enable robust, PPG-exclusive HR monitoring during high-intensity exercise.
Abstract
PPG is the main technology for wearable heart rate (HR) monitoring. However, motion artifacts during intense physical activity reduce its reliability due to spectral overlap with the cardiac signal. This study investigates whether severely contaminated PPG signals can yield reliable HR estimates without auxiliary sensors by leveraging prior knowledge of HR dynamics. We acquired simultaneous PPG and ECG signals from 21 subjects during a maximal cycloergometer test. Using Leave-One-Subject-Out cross-validation, we built HR evolution priors from the ground-truth ECG and applied Dynamic Time Warping (DTW) to align normalized HR curves and estimate a barycenter average. DTW aligns normalized HR curves with minimal error across all subjects, validating robust population-based priors. For each test subject, we combined the PPG Power Spectral Density (PSD) with the prior distribution to generate a "posterior PSD". We identified and ranked candidate HR trajectories using heuristic search within the "posterior PSD" and selected the most likely path. Our approach reduced mean absolute error (MAE) in BPM relative to the ground-truth ECG by a median of 63.3% (IQR: 47.3%-74.6%) compared to a PPG+accelerometer benchmark. These results show that physiological priors and DTW-based alignment enable robust, PPG-exclusive HR monitoring during high-intensity exercise.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- An Agent Architecture with Tools and Memory for Selective Correction of Wrist PPG Heart Rate EstimatesarXiv · 2026
- Improving Wearable PPG Monitoring with Morphology-Aware and Learning-Driven Heartbeat Detection.Sensors (Basel, Switzerland) · 2026
- Interaction-Gated Time-Frequency Learning for Parameter-Efficient PPG-Based Heart Rate EstimationarXiv · 2026
- ARTA: Graph Combinatorial Optimization for Robust Interbeat Interval Estimation from Wearable Electrocardiogram SignalsarXiv · 2026
- Continuous Cuffless Blood Pressure Estimation Using PPG From Methods to Clinical TranslationarXiv · 2026
- Quality and Similarity Indicators for Video-Based Heart Rate and Respiratory Rate Fusion: A Controlled EvaluationarXiv · 2026