Characterization of a cryogenic capacitive tilt sensing module for superconducting gravimeters
Bowen Yang, xinning hu, Feifei Niu, Peiqi Xu, Quansheng Sun, Hao Li, Chunyan Cui, Yuan Zhang,
Key points
From the paper's conclusion- The results show that the module has a good linear response within the range of ±5 mrad.
Abstract
To address the difficulty of directly measuring the tilt of the internal gravity-sensitive unit of a superconducting gravimeter in the liquid helium temperature range, a cryogenic capacitive tilt sensing module was designed. The module uses dual beryllium copper elastic suspension sheets to support an oxygen-free copper movable electrode, and forms a differential capacitance output through the opposite changes in the gaps between the movable electrode and the fixed electrodes on both sides. A theoretical capacitance–tilt angle model was established, the relationships among structural parameters, elastic stiffness, and working range were analyzed, finite element simulations at 293.15 K and 4.2 K were carried out using COMSOL, and calibration was performed through room-temperature platform and test dewar experiments. The results show that the module has a good linear response within the range of ±5 mrad. The differential capacitance–tilt angle sensitivity of the room-temperature platform is 0.0585 pF/mrad, with deviations of 9.16% and 6.85% relative to the theoretical value and the room-temperature simulation value, respectively. Under the 4.2 K test dewar condition, the equivalent differential capacitance–tilt angle sensitivity relative to the external dewar tilt angle is 0.0563 pF/mrad, which is 2.43% lower than the room-temperature test dewar result. Within the 0.01–1 Hz frequency band corresponding to the 1–100 s time scale of the active tilt adjustment process, the root-mean-square equivalent tilt angle noise of the current test chain is 25.145 μrad. This result characterizes the tilt monitoring and readout capability of the module under the current test conditions and provides a reference for subsequent integration with the active tilt control system.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Optimization of external tilt-control setpoints for a superconducting gravimeter based on internal displacement voltage responseChinese Physics B · 2026
- Passive electromagnetic damping using an externally loaded superconducting damping coil for superconducting gravimetersSuperconductor Science and Technology · 2026
- Continuous evaluation of bending strain tolerance along a hundred meter class REBCO tapeSuperconductor Science and Technology · 2026
- Six-degree-of-freedom coupling analysis for the test mass interferometer in spaceborne gravitational wave detectionClassical and Quantum Gravity · 2026
- Comprehensive Literature Review: Optical Fiber Sensing Technologies for Advanced Low-Temperature and Cryogenic Applications.Sensors (Basel, Switzerland) · 2026
- Non-contact temperature sensing and optical scatter in cryogenically-cooled crystalline siliconarXiv · 2026