Passive electromagnetic damping using an externally loaded superconducting damping coil for superconducting gravimeters
Quansheng Sun, xinning hu, Chunyan Cui, Yuan Zhang, Feifei Niu, Peiqi Xu, Bowen Yang, Hao Li,
Key points
From the paper's conclusion- Further analysis shows that this damper can suppress residual oscillations of the levitation test mass caused by step disturbances, 1 Hz harmonic disturbances, and Ricker wavelet acceleration disturbances, and can provide a reference for the design of passive damping structures for external load coils of superconducting gravimeters.
Abstract
Superconducting gravimeters are among the most sensitive relative gravity instruments, but their levitated test mass may exhibit residual oscillations after impact, step and periodic disturbances, affecting the recovery time and low-frequency stability of the instrument. This study proposes a passive electromagnetic damping method based on an externally loaded superconducting damping coil. Axial motion of the levitated sphere changes the magnetic flux through the damping coil, induces current in the damping circuit, and dissipates mechanical vibration energy through the external load resistance. A coupled magnetic-vector-potential finite-element model, external circuit equation and axial equation of motion is developed to analyse the induced current, Joule dissipation and vibration attenuation. The effects of coil position, load resistance and number of turns are then investigated. The results show that these parameters have non-monotonic effects on impact attenuation. Under the present calculation conditions, the strongest attenuation is obtained at a coil position of -15 mm, a load resistance of 4×10 -3 Ω and 50 turns, giving an envelope decay coefficient of approximately 0.261 s -1 . Further analysis shows that this damper can suppress residual oscillations of the levitation test mass caused by step disturbances, 1 Hz harmonic disturbances, and Ricker wavelet acceleration disturbances, and can provide a reference for the design of passive damping structures for external load coils of superconducting gravimeters.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Optimization of external tilt-control setpoints for a superconducting gravimeter based on internal displacement voltage responseChinese Physics B · 2026
- A double-layer Propulsion-Levitation-Guidance (PLG) coil configuration for suppressing electromagnetic force fluctuations in superconducting electrodynamic suspensionSuperconductivity · 2025
- Flux-gradient symmetry controls harmonic generation and nonlinear electromagnetic dampingAIP Advances · 2026
- Characterization of a cryogenic capacitive tilt sensing module for superconducting gravimetersMeasurement Science and Technology · 2026
- Efficient Magnetic Shielding Analysis for the Superconducting Magnet Outer Dewar in EDS SystemsActuators · 2026
- A magnetically levitated conducting rotor with ultra-low rotational damping circumventing eddy lossCommunications Physics · 2025