Calibration Errors and their Impact on Measurement Accuracy in Lifetime based Phosphor Thermometry
Tao Cai, Zheng Dai, Cameron Tropea, Hanyang Qian, Yi Cui, Yingzheng Liu, Di Peng
Key points
From the paper's conclusion- The results demonstrate that the primary error source originates not from the lifetime measurement, but from composite calibration errors, contributing over 99% of the total uncertainty.
Abstract
This study investigates the error propagation in the calibration stage of lifetime based phosphor thermometry and establishes a quantitative framework linking calibration errors to final temperature uncertainty. The results demonstrate that the primary error source originates not from the lifetime measurement, but from composite calibration errors, contributing over 99% of the total uncertainty. Through derivation of error evaluation equations for linear, quadratic, and cubic calibration curves, the dominant role of the covariance coefficient and residuals in uncertainty propagation is elucidated. Experimental validation shows only 3.5% difference in total uncertainty between high and low noise conditions, confirming that environmental noise has minimal impact compared to inherent systematic bias in calibration models. This study ultimately demonstrates that substantial improvements in accuracy must follow a clearly defined optimization hierarchy: first, the measurement accuracy of the reference thermocouple must be ensured; on this basis, the residual term can then be reduced by narrowing the calibration range, selecting an appropriate calibration equation, and/or increasing the density of calibration points.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Assessing and mitigating the impact of fluorescence and camera non-linearity on accurate 2D surface phosphor thermometryMeasurement Science and Technology · 2026
- Aberrations‐Corrected Ratiometric Parameters and PLQYs for Upconversion Thermometry in Hexagonal NaYF 4 :Yb 3+ ,Er 3+ and NaYF 4 :Yb 3+ ,Tm 3+ in Micro and Nanoscale Phosphors Using Novel Integrating Sphere SetupAdvanced Optical Materials · 2026
- Uncertainty-guided optimization of spectral bands for two-color thermometry using laser-induced defect fluorescence in fused silica.Optics express · 2026
- Optical measurement and calibration methods of coagulation analyzerJournal of Physics: Conference Series · 2026
- Improving precision in ratiometric fluorescence thermometry through optical signal uncertainty optimization.Optics letters · 2026
- Intracellular Luminescence Thermometry: A Story of Disagreement, Trust, and HopeACS Physical Chemistry Au · 2026