Assessing and mitigating the impact of fluorescence and camera non-linearity on accurate 2D surface phosphor thermometry
Anthony O. Ojo, David Morrisset, Abhijit Padhiary, Rory M Hadden, Brian Peterson
Key points
From the paper's conclusion- Findings reveal how the 2-D T surface measurements, especially from the burning surface, can be impacted by fluorescence and the camera’s non‑linear response to phosphorescence changes during PMMA decomposition.
Abstract
Accurate knowledge of temperature is fundamental to understanding the heat transfer processes in many applications. Phosphor thermometry (PT) has significantly advanced this understanding by enabling remote temperature measurements. The accuracy of PT measurements is often limited by the accuracy of the reference (e.g., thermocouple; < ±2.5 o C accuracy) used for PT calibration. In practice, challenging applications can exhibit unique features that are absent in the calibration environment and these differences impact the PT accuracy. This study focuses on surface temperature (T surface ) measurements in a flame spread application which presents some attributes not accounted for during PT calibration. By measuring T surface during flame spread over polymethyl methacrylate (PMMA) samples coated with thermographic phosphor (TGP) particles, this paper examines how specific attributes of the application; PMMA fluorescence and thermal decomposition, affect measurement accuracy. Two-dimensional (2-D) T surface measurements are performed using a lifetime-based intensity ratio approach that exploits the intensities of images captured by a CMOS camera during the phosphorescence decay of Gd 3 Ga 5 O 12 :Cr,Ce. Chemiluminescence (CH*) imaging, performed simultaneously with Tsurface measurements, tracks the flame progression during flame spread. The accuracy of 2-D Tsurface measurements is investigated relative to single-point (0-D) Tsurface measurements conducted with thermocouples and with PT (using a photomultiplier tube (PMT) as detector). Findings reveal how the 2-D T surface measurements, especially from the burning surface, can be impacted by fluorescence and the camera’s non‑linear response to phosphorescence changes during PMMA decomposition. 0-D T surface measurements, enabled by a PMT offering better linearity, revealed that deviation of these 2-D T surface measurements can be as high as 120 o C. Mitigation strategies, involving time-gating and isolation of images prone to non-linearities, were implemented; thereby improving the measurement accuracy (~ 6.5 o C mean deviation) of 2-D T surface on the burning surface. Findings here can benefit other applications where the underlying physical processes induce variations that are non-existent during PT calibration.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Soft Lattice and Dual-Emitter Engineering in Cr³⁺ -Doped Fluorides: Achieving Highly Sensitive and High-Fidelity Near-Infrared Optical ThermometryInorganic Chemistry · 2026
- Uncertainty-guided optimization of spectral bands for two-color thermometry using laser-induced defect fluorescence in fused silica.Optics express · 2026
- Use of dual-color optical pyrometry for determining the characteristics of flying nonpoint condensed-phase particles produced during laser ablation of leucosapphireJournal of Optical Technology · 2026
- EXPRESS: High-Accuracy Thermal Diffusivity Measurements by Steady-State and Time Resolved Thermal Lensing: Methodology and Application to Nanoparticle Dispersions.Applied spectroscopy · 2026
- Aberrations‐Corrected Ratiometric Parameters and PLQYs for Upconversion Thermometry in Hexagonal NaYF 4 :Yb 3+ ,Er 3+ and NaYF 4 :Yb 3+ ,Tm 3+ in Micro and Nanoscale Phosphors Using Novel Integrating Sphere SetupAdvanced Optical Materials · 2026
- Multifunctional Role of Eu³⁺ in NaSrBiTeO₆ Double Perovskites for Solid-State Lighting, Temperature Sensing, and Latent Fingerprint ApplicationsACS Applied Optical Materials · 2025