Comparing the Single Maddox Rod Test to the Alternate Cover Test in Normal Individuals.
Victoria Erickson, Kimberly Merrill, Collin M McClelland, Christian Larson, Michael S Lee
Department of Ophthalmology and Visual Neurosciences, University of Minnesota, Minneapolis, Minnesota.
Key points
From the paper's conclusion- The difference between each participants' measurements at near (ΔX') was 4.44 ± 3.87 Δ (p < .001) meaning each participant was an average of 4.44 Δ more exophoric at near with the PSMRT compared to their measurement at near with the PACT. There was no significant difference between PSMRT and PACT at distance (-0.09 ± 1.33 Δ (p > .5)).
Abstract
PURPOSE: The single Maddox rod test (SMRT) is a rapid subjective method for detecting ocular misalignment. In this study, we compared the prism single Maddox rod test (PSMRT) to the prism alternate cover test (PACT) in normal individuals to see if there was any disagreement. METHODS: Ocular alignment was measured at distance and near with the PSMRT and PACT in 52 normal participants. Secondary measurements included visual acuity, near point of convergence, and stereoacuity. RESULTS: The difference between each participants' measurements at near (ΔX') was 4.44 ± 3.87 Δ (p < .001) meaning each participant was an average of 4.44 Δ more exophoric at near with the PSMRT compared to their measurement at near with the PACT. There was no significant difference between PSMRT and PACT at distance (-0.09 ± 1.33 Δ (p > .5)). DISCUSSION: Among visually normal participants, the PSMRT measures more exophoria at near than the PACT. This difference may affect the interpretation of near alignment in various clinical settings, especially when evaluating patients with symptoms suggestive of convergence insufficiency. The PSMRT should be used with caution and be confirmed with the PACT when clinically indicated.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Agreement between digital ocular alignment measurement devices and the prism alternate cover test in horizontal strabismus.International ophthalmology · 2026
- Short-Term Residual Myopic Bias Measured by Open-Field Autorefraction After 10-Second Myopic Overcorrection in Young Myopic Adults.Vision (Basel, Switzerland) · 2026
- Repeatability of near point of fixation disparity test.Clinical & experimental optometry · 2026
- Multifocal electroretinography assessment of retinal responses to myopic defocus lenses.PeerJ · 2026
- Subjective Peripheral Refraction Using a Gabor-Based Duochrome Test in Young Adults: An Exploratory Study.Life (Basel, Switzerland) · 2026
- Assessment of Visual Quality Changes as a Result of Spectacle Misalignment.Vision (Basel, Switzerland) · 2026