Multifocal electroretinography assessment of retinal responses to myopic defocus lenses.
Mohammed Alhazmi, Mohammed Althomali, Muteb Alanazi, Wafa Alotaibi, Eman Alghamdi, Ali Almustanyir, Fahd Alqahtani, Maria Liu
Optometry Department, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia. · Ophthalmology Department, King Saud University Medical City, Riyadh, Saudi Arabia.
Key points
From the paper's conclusion- The tested defocus segment lens designs did not produce statistically detectable alterations in first order mfERG parameters in structurally intact emmetropic eyes under brief exposure. Although the analytical framework demonstrated sufficient sensitivity to identify medium to large electrophysiological effects, the current design may lack resolution for subtle retinal adaptations. Future investigations incorporating larger cohorts, prolonged optical exposure, and nonlinear analytical techniques in ametropic populations will be necessary to determine whether clinically relevant myopia control mechanisms correspond to measurable electrophysiological modulation.
Abstract
AIM: To evaluate the short-term retinal electrical responses elicited by defocus segment lenses in emmetropic eyes using multifocal electroretinography (mfERG). MATERIALS & METHODS: A prospective cross-sectional study enrolled 14 young, healthy emmetropic participants aged 18 to 22 years with no ocular or systemic diseases. Comprehensive eye examinations were conducted, and mfERG recordings were obtained using six different condition scenarios. Retinal responses were analyzed across hexagon ring groupings defined by angular extent (Ring 1: 2.5°, Ring 2: 7.5°, Ring 3: 14°, Ring 4: 22°, Ring 5: 30°). Statistical analysis was performed to compare retinal responses across different lens types and retinal regions. RESULTS: No significant differences in retinal electrical responses were detected across the six lens conditions for negative (N1) latency (ms), positive (P1) latency (ms), or P1 amplitude (nV/deg2) (all p > 0.05). Regional variations in amplitude and latency across concentric retinal rings were observed but reflected expected normative mfERG gradients independent of lens type. CONCLUSION: The tested defocus segment lens designs did not produce statistically detectable alterations in first order mfERG parameters in structurally intact emmetropic eyes under brief exposure. Although the analytical framework demonstrated sufficient sensitivity to identify medium to large electrophysiological effects, the current design may lack resolution for subtle retinal adaptations. Future investigations incorporating larger cohorts, prolonged optical exposure, and nonlinear analytical techniques in ametropic populations will be necessary to determine whether clinically relevant myopia control mechanisms correspond to measurable electrophysiological modulation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Sustained Plus Lens Defocus Alters Retinal Responses and Ciliary Muscle Morphology In Myopes and Near-emmetropes.Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) · 2026
- Biomimetic computational modelling of retinal ganglion cell responses to contact lens designs with refractive and opaque non-refractive features.BMC ophthalmology · 2026
- Factors Influencing Refractive Severity and Visual Improvement in Pediatric Unilateral High Myopia With Myelinated Retinal Nerve Fibers.Eye & contact lens · 2026
- Subjective Peripheral Refraction Using a Gabor-Based Duochrome Test in Young Adults: An Exploratory Study.Life (Basel, Switzerland) · 2026
- Retinal Sensitive Areas in Myopia Control: Identifying the Potential Retinal 'Sweet Spot'-A Scoping Review.Clinical ophthalmology (Auckland, N.Z.) · 2026
- Short-term axial eye length changes after imposed defocus in emmetropes, myopes and hyperopesVision Research · 2026