Effect of monocular impaired visual acuity across OptonetTM and non-digital clinical stereotests.
Jignasa Mehta, Anna O'Connor, Roisin Buckels
School of Allied Health Professions and Nursing, University of Liverpool, Liverpool, UK.
Key points
From the paper's conclusion- A new testing system Optonet includes a stereo test which has not been evaluated in terms of the impact of blur; therefore, the aim of this study was to compare the effect of simulated impaired visual acuity across differing stereotests including Optonet.
Abstract
Background: Impaired depth perception can be caused by monocular blur and is assessed with a range of stereotests, but differences in test presentation result in varying outcomes. A new testing system Optonet includes a stereo test which has not been evaluated in terms of the impact of blur; therefore, the aim of this study was to compare the effect of simulated impaired visual acuity across differing stereotests including Optonet. Method: Participants aged ≥18 years with visual acuity ≤0.3 logMAR in either eye and <0.2 logMAR interocular difference were included. Visual acuity (VA) was tested using the ETDRS test for near (40cms) and distance (4 meters). Stereoacuity was measured with Frisby, TNO, and Optonet, a random dot-based test on an iPad with red/blue glasses. Blur was induced with Bangerter foils 0.2 and 0.4 and VA and stereodata were remeasured. An arbitrary value of 5000" of arc was given if stereoacuity was not measurable. Results: Twenty-five participants (23 females and 2 males), median age 21 (IQR:2, Range 19-38), were included. Near VA (Median ± IQR) with 0.2 and 0.4 Bangerter foil (right eye) was 0.36 ± 0.18 and 0.50 ± 0.19 logMAR, respectively, with 0.00 ± 0.15 logMAR in left eye. TNO demonstrated the largest degradation compared to Frisby and Optonet (no foil: 60" (TNO) 20" (Frisby) 40" (Optonet), 0.2 foil: 240" (TNO) 40" (Frisby) 119" (Optonet), 0.4 foil: 2000" (TNO) 85" (Frisby) 158" (Optonet)). Significant differences in the amount that stereoacuity was reduced occurred between Frisby and TNO (p < .05, Friedman's two-way analysis of variance). Conclusion: Differences in stereoacuity are evident across stereotests under simulated conditions of blur. For accurate repeatable measures of stereoacuity, a consistent stereotest should be used. Random dot tests such as TNO and Optonet are impacted more by blur than Frisby with Optonet showing the greatest sensitivity to blur.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Stereoacuity Assessment in Children: Testability, Repeatability, and Inter-Test Agreement Among TNO, Frisby and YRDS3 StereotestsChildren · 2026
- Nil Stereoacuity in Amblyopia and Strabismus: A Methodological Systematic Review.Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) · 2026
- Description and Evaluation of a Visual Acuity Assessment Paradigm Based on Spatial Frequency-Modulated Form Discrimination.Translational vision science & technology · 2026
- The relationship between motor fusion and stereoacuity in adults with normal binocular single vision.Strabismus · 2026
- Visual acuity measured with a 3 mm pupil and Maxwellian view for subjective vs. objective focus in patients with exudative retinal disease.Biomedical optics express · 2026
- Comparison of the Melbourne rapid fields-web device-independent online perimeter and the octopus 600 perimeter in glaucoma patients.Frontiers in ophthalmology · 2026