Nil Stereoacuity in Amblyopia and Strabismus: A Methodological Systematic Review.
Laura Asensio-Jurado, Marc Argilés, Xavier Molinero, Bernat Sunyer-Grau, Dennis M Levi
Centre for Sensors, Instruments and Systems Development (CD6), Universitat Politècnica de Catalunya · Barcelona Tech (UPC), Terrassa, Spain. laura.asensio@upc.edu. · Centre for Sensors, Instruments and Systems Development (CD6), Universitat Politècnica de Catalunya · Barcelona Tech (UPC), Terrassa, Spain.
Key points
From the paper's conclusion- The expression and reporting of stereoacuity are highly heterogeneous, and this introduces an undetectable source of variability in evidence synthesis. A five-item minimum reporting standard is proposed covering the test, and its disparity range, the prevalence and definition of nil, its analytical treatment and the notation used, to make these choices explicit for authors, reviewers and editors.
Abstract
PURPOSE: Stereoacuity is increasingly used as an outcome measure in amblyopia and strabismus research, yet the way unmeasurable ('nil') values are handled, and the way stereoacuity is expressed vary across studies in ways that compromise the comparability of published findings. This review quantifies that variability and proposes a minimum reporting standard. METHODS: A systematic review was conducted following PRISMA guidelines (OSF: 10.17605/OSF.IO/TY7FG), including studies published from 2010 onward that reported stereoacuity as an outcome in amblyopia or strabismus. For each study, the notation used to express stereoacuity was coded, whether the baseline prevalence of nil was reported and how nil observations were handled analytically. Reporting completeness was scored from 0 to 3 and its changes over time were assessed. RESULTS: Across 79 studies (2010-2026; 7,466 participants), the baseline prevalence of nil could not be determined in 54%. Among studies imputing a fixed value to nil, ten values were used, from 400 to 100,000 arcsec (a 250-fold span, eight octaves). Notation varied across two logarithmic bases and untransformed arcsec, and scale convention was strongly associated with nil-handling strategy ( χ ² = 24.46, p < 0.001), defining two methodological ecosystems that yield non-comparable results. Reporting completeness declined over the review period (Spearman's ρ = -0.37, p < 0.001). In simulations, these inconsistencies produced up to an 8.4-fold difference in apparent effect size for an identical clinical change. CONCLUSIONS: The expression and reporting of stereoacuity are highly heterogeneous, and this introduces an undetectable source of variability in evidence synthesis. A five-item minimum reporting standard is proposed covering the test, and its disparity range, the prevalence and definition of nil, its analytical treatment and the notation used, to make these choices explicit for authors, reviewers and editors.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Stereoacuity Assessment in Children: Testability, Repeatability, and Inter-Test Agreement Among TNO, Frisby and YRDS3 StereotestsChildren · 2026
- Repeatability of near point of fixation disparity test.Clinical & experimental optometry · 2026
- Automated and Objective Detection of Binocular Vision with a VR-Based Medical Device.Klinische Monatsblatter fur Augenheilkunde · 2026
- Diagnostic Utility of Accommodative Measurements by Nott Dynamic Retinoscopy in Children with Unilateral Amblyopia.Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) · 2026
- Accuracy and precision of visual acuity tests: A systematic review and meta-analysis across testing strategiesmedRxiv · 2026
- Evaluation of the glasses-free Bernell evaluation of stereoacuity test.Journal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus · 2026