A temporary fix: assessing the safety, efficacy, and various applications of temporary externalized pacemakers.
Levi Schiefer, Gillian Sheppard, Alisa King, Javier Banchs, Jose E Exaire, Robert J Widmer, Timothy A Mixon
Department of Internal Medicine, Baylor Scott & White Medical Center - Temple, Temple, Texas, USA. · Division of Cardiology, Baylor Scott & White Medical Center - Temple, Temple, Texas, USA.
Key points
From the paper's conclusion- Temporary pacing using a screw-in lead affixed to an external generator is safe, effective, and reversible across multiple clinical scenarios, allowing sufficient time to assess the need for permanent pacing.
Abstract
BACKGROUND: Temporary active-fixation pacemakers (TAF-PMs), consisting of a screw-in pacing lead connected to an external generator, may offer advantages over conventional balloon-tipped temporary pacemakers, including more secure lead placement, greater patient mobility, and reduced need for intensive care monitoring. We evaluated the safety and clinical utility of this strategy across multiple pacing indications. METHODS: We conducted a single-center, retrospective study of 100 adults who underwent TAF-PM placement between June 2019 and November 2024. Through chart review, data were collected on demographics, pacing indications, duration of temporary pacing, complications, and subsequent need for permanent pacemaker implantation (PPMI). The primary outcome was successful discontinuation of temporary pacing without subsequent PPMI. RESULTS: Pacing indications included spontaneous progression of conduction system disease (60%), transcatheter aortic valve replacement (TAVR)-related conduction abnormalities (12%), acute myocardial infarction (AMI)-related conduction abnormalities (12%), and ongoing infection precluding PPMI (16%). Thirty-eight patients (38%) did not undergo subsequent PPMI. Among patients with TAVR- and AMI-related conduction abnormalities, 75% avoided PPMI. Three patients (3%) experienced lead dislodgement. No new infections, lead perforations, significant bleeding, or cardiac arrests attributable to the TAF-PM strategy were documented. CONCLUSION: Temporary pacing using a screw-in lead affixed to an external generator is safe, effective, and reversible across multiple clinical scenarios, allowing sufficient time to assess the need for permanent pacing.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Transapical epicardial temporary pacemaker lead implantation in patients with transapical TAVI.Open heart · 2026
- Temporary Active Fixation Leads in Transcatheter Aortic Valve Replacement Patients With Baseline Right Bundle Branch Block.Structural heart : the journal of the Heart Team · 2026
- Incidence of Pacing-Induced Cardiomyopathy in Active-Fixation Leadless Pacemakers.Journal of cardiovascular electrophysiology · 2026
- Case Report: Double-click on the ventricle: ventricular safety pacing triggered by right atrial lead dislodgement in a patient after right atrial tumor resection.Frontiers in cardiovascular medicine · 2026
- A decade of leadless pacemaker implantation: technical performance, safety and device longevityEuropean Heart Journal · 2026
- Transvenous leadless pacemaker extraction: When, who, where, and how?Kardiologia Polska · 2026