Marinelli Equation vs. DIN 6861-1: Comparison of the Achieved Therapeutic Thyroid Dose after Radioiodine Therapy Using Different Pretherapeutic Dosimetry.
Patrick Heilfort, Olga Varlamova, Max Kranick, Jan Bredow, Michael Starke
Medical University of Lausitz - Carl Thiem, Clinic for Nuclear Medicine, BB, Germany, Cottbus.
Key points
From the paper's conclusion- The use of DIN 6861-1:2021-11 is associated with improved prediction of the thyroid dose compared with the Marinelli equation and may contribute to more precise individualized planning of radioiodine therapy in patients with benign thyroid diseases.
Abstract
AIM: Pretherapeutic dosimetry is an essential component of individualized radioiodine therapy. This study aimed to compare radioiodine therapies planned according to the Marinelli equation or DIN 6861-1:2021-11 with regard to the deviation of the planned and achieved thyroid doses in patients with benign thyroid diseases. METHODS: The relative deviation of the achieved thyroid dose during radioiodine therapy from the pretherapeutically planned dose was analyzed according to the applied dosimetric method. Patient cohorts with goiter, recurrent goiter, disseminated and focal thyroid autonomy and autoimmune thyroid disease were evaluated. The cohorts were compared using the Mann-Whitney U- test. RESULTS: For goiter, recurrent goiter, disseminated thyroid autonomy and focal thyroid autonomy, radioiodine therapies planned according to DIN 6861-1:2021-11 were associated with significantly smaller deviations between the planned and achieved thyroid doses than therapies planned according to the Marinelli equation. Depending on the diagnostic group, the mean relative deviation was approximately 15 to 32 percentage points lower in the DIN cohorts. The DIN cohorts also showed less variability in dose deviations. In patients with autoimmune thyroid disease, no statistically significant differences of the mean relative deviation were observed between the dosimetric methods. However, variability was also lower in the DIN cohorts. CONCLUSION: The use of DIN 6861-1:2021-11 is associated with improved prediction of the thyroid dose compared with the Marinelli equation and may contribute to more precise individualized planning of radioiodine therapy in patients with benign thyroid diseases.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Feasibility of pre-treatment dosimetry using Tc-99m in radioiodine therapy for Graves' disease and multinodular goitre: a comparison with the fixed-activity approach.Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2026
- A Novel Protocol for Pre-Treatment Diagnostic 131I Scan Within 24 Hours Post-Second rhTSH Administration to Guide Radioiodine Therapy in Differentiated Thyroid Cancer.Thyroid : official journal of the American Thyroid Association · 2026
- Evaluation of Radioiodine (I-131) Therapy Success in Different Etiological Forms of Hyperthyroidism and Analysis of Response According to Administered Dose.Cureus · 2026
- Combined Maximum Tolerated Activity and Lesion-based Dosimetry for Personalized Radioiodine Therapy in Metastatic Differentiated Thyroid Carcinoma: An Early Institutional Experience.Molecular imaging and radionuclide therapy · 2026
- A cohort electron blood self-dose fraction and its propagated uncertainty for ¹²⁴I PET pre-therapy dosimetry in radioiodine therapy of differentiated thyroid cancer.Annals of nuclear medicine · 2026
- The effects of stimulated thyroglobulin/ thyroid-stimulating hormone ratio and N1b status on the efficacy of the first I-131 treatment in patients with differentiated thyroid cancer.PloS one · 2026