Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)

Feasibility of pre-treatment dosimetry using Tc-99m in radioiodine therapy for Graves' disease and multinodular goitre: a comparison with the fixed-activity approach.

Manuela Meraldi, Chiara Romanò, Gaia Muti, Claudia Carbonini, Virginia Piva, Grazia Cabrini, Selene Capitanio, Annalisa Franchini,

Postgraduate School of Medical Physics, Università degli Studi di Milano, Via Giovanni Celoria 16, 20133 Milan, Italy; Department of Medical Physics, ASST Grande Ospedale Metropolitano Niguarda, Piazza Ospedale Maggiore 3, 20162 Milan, Italy. Electronic address: manuela.meraldi@unimi.it. · Department of Medical Physics, ASST Grande Ospedale Metropolitano Niguarda, Piazza Ospedale Maggiore 3, 20162 Milan, Italy.

Key points

From the paper's conclusion
  • 99mTc pre-treatment dosimetry proved to be a feasible alternative to 131I. This approach enables tailoring activity estimation and reducing the risk of excessive absorbed dose administration compared to a fixed-activity approach.

Abstract

BACKGROUND AND PURPOSE: In radioiodine therapy for hyperthyroidism, patient-specific activity determination is recommended. This study investigated whether a 99mTc thyroid uptake measurement at 20 min (99mTc RIU(20 min)) could be correlated to 131I uptake at 24 h (131I RIU(24 h)) and used to estimate the activity required to deliver the prescribed absorbed dose. The absorbed dose delivered with 99mTc-based activity was compared to that delivered with the fixed activity recommended in absence of prior evaluation at our center. MATERIALS AND METHODS: A logarithmic conversion formula relating 99mTc RIU(20 min) to 131I RIU(24 h) was derived from 66 patients with Graves' disease and multinodular goitre who underwent both 99mTc and 131I pre-treatment dosimetry at our center. 99mTc RIU(20 min) was assessed via scintigraphy, while 131I RIU(24 h) with a dedicated probe. Recommended activities were estimated using EANM formulas. In the same group of patients, absorbed doses delivered with the tailored approach were compared to those delivered with the fixed-activity method. RESULTS: The relationship between 99mTc RIU(20 min) and 131I RIU(24 h) was described by the equation 131I RIU(24 h) = 12.07ln(99mTc RIU(20 min)) + 31.93. The administration of a fixed activity resulted in 50% of patients receiving absorbed doses higher than 400 Gy, whereas 99mTc-based dosimetry reduced this proportion to 10%. The median fixed-to-tailored absorbed dose discrepancy was 26% (range: -78% to 555%), highlighting the dosimetric variability introduced by the standard approach. CONCLUSION: 99mTc pre-treatment dosimetry proved to be a feasible alternative to 131I. This approach enables tailoring activity estimation and reducing the risk of excessive absorbed dose administration compared to a fixed-activity approach.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.