A cohort electron blood self-dose fraction and its propagated uncertainty for ¹²⁴I PET pre-therapy dosimetry in radioiodine therapy of differentiated thyroid cancer.
Mohamed Badawy, Lachlan McIntosh, Price Jackson, Ian Jong
Radiology Department, Monash Health, 246 Clayton Road, Clayton, VIC, 3168, Australia. mohamed.badawy@monashhealth.org. · Prostate Cancer Theranostics and Imaging Centre of Excellence, Molecular Imaging and Therapeutic Nuclear Medicine, Cancer Imaging, Peter MacCallum Cancer Centre, Melbourne, VIC, Australia.
Key points
From the paper's conclusion- A cohort β fraction of 84.3 ± 4.8% is proposed as a fall-back reference for blood-free prescribing in DTC radioiodine therapy. Because the estimator's error is multiplicative on the estimate, a prescribing cap must come from the lower tail of that error, giving approximately 1.0-1.2 Gy in this cohort. No 95% coverage is demonstrated at this sample size, and the cap is offered as an exploratory observation requiring local confirmation rather than a validated threshold. The decomposition is imaging-modality agnostic for ¹³¹I clearance studies and therefore potentially applicable to low-dose ¹³¹I SPECT, although no SPECT data were analysed here.
Abstract
OBJECTIVE: Pre-therapy blood-marrow dosimetry for ¹³¹I treatment of differentiated thyroid cancer (DTC) requires serial imaging and blood sampling, limiting clinical adoption. When blood data are unavailable, operators fall back to fixed or imaging-only prescribing, usually without an explicit uncertainty bound. We characterise the cohort electron blood self-dose fraction (βfrac) in a single-centre ¹²⁴I PET cohort and quantify the uncertainty incurred by substituting that reference for patient-specific blood data. METHODS: Retrospective single-centre analysis of 18 pre-therapy ¹²⁴I PET courses in 15 DTC patients with paired serial venous blood-counting, all prepared by thyroid-hormone withdrawal. Time-activity curves were fitted in the ¹³¹I therapy frame following the EANM Standard Operational Procedure, separating Dblood into its electron (β, blood self-dose) and photon (γ, body cross-fire) components. The substitution uncertainty was propagated analytically, then validated against patient-level errors by leave-one-patient-out cross-validation. RESULTS: The cohort β fraction was 84.3 ± 4.8% across 18 courses (mean ± SD; median 85.4%; 95% CI 82.0-86.7%), and 84.4 ± 4.6% over the 15 patients. The β fraction decreased with body weight (- 0.113 pp/kg, p = 0.019), although not significantly when reduced to one value per patient (p = 0.118); the association is therefore exploratory. Substitution gave a per-patient 1-σ uncertainty on the imaging-only Dblood estimate of ≈ 30%. Under leave-one-patient-out cross-validation the mean absolute percentage error was 26.3% and the RMSE 32.7%, with 12 of 18 courses within ± 30% of their reference. CONCLUSIONS: A cohort β fraction of 84.3 ± 4.8% is proposed as a fall-back reference for blood-free prescribing in DTC radioiodine therapy. Because the estimator's error is multiplicative on the estimate, a prescribing cap must come from the lower tail of that error, giving approximately 1.0-1.2 Gy in this cohort. No 95% coverage is demonstrated at this sample size, and the cap is offered as an exploratory observation requiring local confirmation rather than a validated threshold. The decomposition is imaging-modality agnostic for ¹³¹I clearance studies and therefore potentially applicable to low-dose ¹³¹I SPECT, although no SPECT data were analysed here.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Pretherapeutic quantitative I-131 SPECT/CT for blood and tumour dosimetry in thyroid cancer patients with bone metastases: a pilot feasibility study.EJNMMI physics · 2026
- Dose-activity relationship in [131I]NaI therapy for differentiated thyroid carcinoma.Annals of nuclear medicine · 2026
- Patient-Specific Dosimetry for [131I]NaI Therapy in End-Stage Renal Disease: Segmented Time-Activity Analysis, Hemodialysis Clearance, and Radiation Safety.Journal of nuclear medicine technology · 2026
- Lifetime attributable cancer risk assessment in pediatric patients undergoing I-124 PET for differentiated thyroid cancer.Radiation protection dosimetry · 2026
- Radiobiological dosimetry using hybrid imaging-derived spatiotemporal dose distributions for131I therapy of metastatic thyroid cancer.Physics in medicine and biology · 2026
- Optimal timing of post-therapeutic [131I]NaI whole-body scintigraphy in predominantly low- and intermediate-risk differentiated thyroid cancer: a secondary analysis of prospectively acquired data and a structured literature review.BMC medical imaging · 2026