Axial Compression Behaviour of Locking Plate Constructs in Different Fixation Functions in the Canine Femur.
Bianca Marfil Bregadioli, Anderson Fernando de Souza, Thales Bregadioli, Renato Otaviano do Rego, Adan Peres Cabreira, Gabriel Antonio Covino Diamante, André Luiz do Valle De Zoppa
School of Veterinary Medicine and Animal Science, University of São Paulo, Department of Surgery, Brazil. · Orthosupport Pet, Brazil.
Key points
From the paper's conclusion- Fixation function strongly influences the mechanical behaviour of locking plate constructs. Restoration of the bone column promotes load sharing and is associated with increased construct stiffness under axial compression. Bridge fixation places greater mechanical demand on the implant, increasing susceptibility to plastic deformation.
Abstract
OBJECTIVE: The objective of this study is to compare the axial compression behaviour of locking plate constructs applied with different fixation functions in the canine femur, focusing on construct stiffness, resistance to plastic deformation, and bone-implant load sharing. METHODS: Femora were allocated to four groups: intact (control), compression, neutralization, or bridge fixation using a locking plate. Compression and neutralization constructs restored the bone column, whereas bridge fixation eliminated load sharing by spanning a diaphyseal defect. All specimens underwent axial compression testing until failure, with stiffness, apparent elastic limit, maximum load to failure, and failure modes recorded. RESULTS: Construct stiffness varied according to fixation function. Intact femora and compression constructs demonstrated the highest stiffness values and were not significantly different from each other. Bridge constructs showed significantly lower stiffness values than intact, compression, and neutralization constructs. Intact femora also demonstrated higher apparent elastic limit and maximum load values than neutralization and bridge constructs. Plate bending was the predominant failure mode, especially in bridge fixation. CONCLUSION: Fixation function strongly influences the mechanical behaviour of locking plate constructs. Restoration of the bone column promotes load sharing and is associated with increased construct stiffness under axial compression. Bridge fixation places greater mechanical demand on the implant, increasing susceptibility to plastic deformation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- From load-bearing to load-sharing: contact-driven transitions in locked plate constructs.Archives of orthopaedic and trauma surgery · 2026
- Investigation of optimal placement of locking attachment plate in periprosthetic femoral fractures : a biomechanical comparative study.Bone & joint research · 2026
- Two headless cannulated screws have a higher maximum failure load than screw-and-pin fixation at a 70° fracture angle in 3-dimensionally printed canine femoral neck models.American journal of veterinary research · 2026
- Biomechanical comparison of prophylactic fixation methods following excision of benign aggressive tumors of the femoral neck using composite bone models.Clinical biomechanics (Bristol, Avon) · 2026
- A novel stiffness-distribution-controlled hybrid locking compression plate for osteoporotic midshaft clavicle fractures: a finite element study.BMC musculoskeletal disorders · 2026
- Axial Stiffness Advantage of Nail–Plate Fixation in 101 Patient-Specific Femora: A Finite Element StudyJournal of Clinical Medicine · 2026