From load-bearing to load-sharing: contact-driven transitions in locked plate constructs.
Marianne Hollensteiner, Martina Schindler, Markus Greinwald, Mischa Mühling, Dirk Baumeister, Peter Augat
Institute for Biomechanics, Paracelsus Medical University, Salzburg, Austria. marianne.hollensteiner@bgu-murnau.de. · Institute for Biomechanics, Berufsgenossenschaftliche Unfallklinik Murnau, Murnau am Staffelsee, Germany.
Key points
From the paper's conclusion- In conclusion, load-dependent contact events were associated with distinct transitions in construct stiffness, plate-surface strain progression, and interfragmentary motion, complementing the observed associations between geometric parameters and initial mechanical behavior.
Abstract
Locked plate osteosynthesis functions as an internal fixator, yet load-induced plate-bone and fragment-fragment contacts - key transitions from load-bearing to load-sharing - remain poorly characterized. This study quantified their effects on construct stiffness, plate strain, and interfragmentary motion under axial loading. Twenty-seven configurations were tested using epoxy-glass surrogate bone fixed with titanium LCP plates, varying fracture gap (3-9 mm), working length (49-121 mm), and plate-bone distance (0-3 mm). Digital image correlation measured strain and motion. Contact events were identified manually from characteristic transitions in the force-displacement response, supported by corresponding changes in plate-surface strain progression. Geometric parameters dominated initial stiffness (125-442 N/mm), decreasing with plate elevation and working length in elevated setups. Within the investigated load range up to 600 N, 16/27 configurations showed non-linear transitions associated with contact events: fragment-fragment contact caused pronounced stiffness increases and strain stagnation at the fracture gap, whereas plate-bone contact was associated with local plate-surface strain stagnation at the location overlying the contact while strain at the fracture gap continued to increase. Interfragmentary motion stagnated after contact, confirming contact-dependent shifts in load transfer. Response surface regression explained 81.9% of the variance in initial stiffness and 89.6% of the variance in axial interfragmentary motion, identifying outcome-specific associations with geometric parameters and selected interaction terms. In conclusion, load-dependent contact events were associated with distinct transitions in construct stiffness, plate-surface strain progression, and interfragmentary motion, complementing the observed associations between geometric parameters and initial mechanical behavior.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Axial Compression Behaviour of Locking Plate Constructs in Different Fixation Functions in the Canine Femur.Veterinary and comparative orthopaedics and traumatology : V.C.O.T · 2026
- Biomechanical effects of far-cortex over-penetration in locking plate fixation: A finite element study.Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2026
- Biomechanical comparison of mini-plate and screw fixation in minimally invasive distal metatarsal osteotomy for hallux valgus : a finite element and cadaveric study.Bone & joint research · 2026
- Biomechanical Evaluation of Patient-Specific Titanium Fixation Systems for Segmental Le Fort I Osteotomy: A Finite Element Analysis.Journal of functional biomaterials · 2026
- Biomechanical and finite element analysis of a novel annular multi-axial locking plate for patellar fracture fixation.Journal of orthopaedic surgery and research · 2026
- Strain Analysis of Pin Insertion Sites in an External Fixation Model of the Ankle Joint Using Digital Image Correlation: Quantitative Assessment of Pin Loosening RiskIndian Journal of Orthopaedics · 2026