Minimally Invasive Distal Metatarsal Osteotomy: Does Screw Design, Number, and Position Matter?
Ali A Khazaal, Nathaniel Helwig, Ashley Thai, Sayud Ali, Ame Anteyi, Noman A Siddiqui
Department of Orthopedic Surgery, Rubin Institute of Advanced Orthopedics, International Center for Limb Lengthening, 2401 West Belvedere Ave. Baltimore, MD 21215. · Department of Orthopedic Surgery, Rubin Institute of Advanced Orthopedics, International Center for Limb Lengthening, 2401 West Belvedere Ave. Baltimore, MD 21215. Electronic address: nsiddiqui@lifebridgehealth.org.
Key points
From the paper's conclusion- Infection rates did not differ significantly. Compression screws were associated with earlier union, although this association was attenuated after calendar year adjustment. Screw position was correlated with time to union, while additional and compression screws were associated with higher rates of hardware complications.
Abstract
BACKGROUND: Optimal fixation for minimally invasive distal metatarsal osteotomy remains uncertain. STUDY DESIGN: Retrospective cohort study PURPOSE: Examine associations of screw number and design with time to first documented radiographic union and explores screw-position correlations with time to union and postoperative complications. METHODS: Adults undergoing hallux valgus correction from January 2019 to March 2025 were included; prior correction, fixation-free surgery, and inadequate radiographic follow-up were exclusions. RESULTS: Among 221 patients (273 feet), time to union did not differ between screw number (difference, -1.38 weeks; 95% CI, -4.42 to 1.66; p = 0.372). Compression screws were associated with shorter time to union than non-compression screws (difference, -5.01 weeks; 95% CI, -8.48 to -1.54; p = 0.005), including in multivariable analysis (p = 0.012), but not after calendar year adjustment (p = 0.163). Greater osteotomy-to-proximal screw distance correlated with longer time to union (ρ = 0.266; p < 0.001), whereas greater screw head-to-first tarsometatarsal joint distance correlated with shorter union time (ρ = -0.314; p < 0.001). Hardware irritation and removal were more frequent in 2 versus 1-screws (13% vs 1%, p = 0.002; 12% vs 1%, p = 0.004) and compression versus non-compression constructs (16% vs 2%, p < 0.001; 15% vs 2%, p = 0.001). CONCLUSION: Infection rates did not differ significantly. Compression screws were associated with earlier union, although this association was attenuated after calendar year adjustment. Screw position was correlated with time to union, while additional and compression screws were associated with higher rates of hardware complications. LEVEL OF CLINICAL EVIDENCE: Therapeutic Level 3.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Biomechanical Evaluation of Crossed Screw Fixations With Different Head Designs for First Tarsometatarsal Joint Arthrodesis.Foot & ankle specialist · 2026
- A pilot study of a novel screw design for early callus formation in minimally invasive hallux valgus correctionBMC Musculoskeletal Disorders · 2026
- Biomechanical comparison of mini-plate and screw fixation in minimally invasive distal metatarsal osteotomy for hallux valgus : a finite element and cadaveric study.Bone & joint research · 2026
- High reoperation rates following first metatarsophalangeal joint arthrodesis using a modern compression plating system with a retrograde integrated lag screw.Foot (Edinburgh, Scotland) · 2026
- Headless Compression Screws May Reduce Symptomatic Hardware After Medial Malleolus Fixation: A Comparative Cohort Study.Journal of orthopaedic trauma · 2026
- Influence of Screw Length, Diameter, and Immobilization on Percutaneous Scaphoid Fixation: A Retrospective Study of 249 Acute Scaphoid Fractures.Hand surgery & rehabilitation · 2026