A pilot study of a novel screw design for early callus formation in minimally invasive hallux valgus correction
Dong-Oh Lee, Ji-Young Jeon, Sang-Gyo Seo, Tae Byung Kang, JeongHwan Lee
Key points
From the paper's conclusion- These findings support further biomechanical and prospective clinical investigation of fixation configuration in minimally invasive hallux valgus osteotomy.
Abstract
Background Minimally invasive hallux valgus correction surgery is gaining popularity; however, the influence of fixation configuration on early osteotomy healing remains insufficiently understood. We developed a novel screw design with a segmented geometry intended to modify the mechanical environment of the osteotomy while maintaining bone purchase in the first metatarsal head. This study aims to evaluate the early radiographic healing characteristics and radiographic correction achieved using this novel screw construct. Methods Twenty-one patients underwent bilateral minimally invasive hallux valgus surgery between 2024 and 2025. A bilateral intra-patient controlled design was used, with one foot fixed using two conventional screws (Group A) and the contralateral foot fixed using one conventional screw and one novel screw (Group B). Fifteen patients who completed a minimum of one year of follow-up were retrospectively reviewed. Hallux valgus angle (HVA), intermetatarsal angle (IMA), early callus formation, final radiographic union, complications, and patient satisfaction were evaluated. Results The mean HVA improved from 28.8° to 4.6° in Group A and from 29.3° to 4.5° in Group B (both p < 0.001). The mean IMA improved from 12.1° to 4.9° in Group A and from 12.2° to 5.0° in Group B (both p < 0.001). No significant differences were observed between the groups in final HVA or IMA. At the early postoperative radiographic assessment, approximately 4 months, callus formation was significantly greater in Group B than in Group A ( p = 0.020). Complete radiographic union was observed in 29 of 30 feet at final follow-up; one foot in Group A demonstrated partial union. One symptomatic hardware complication requiring removal occurred in Group A. Conclusions The novel screw construct was associated with greater early radiographic callus formation while maintaining correction of hallux valgus deformity in this pilot study. These findings support further biomechanical and prospective clinical investigation of fixation configuration in minimally invasive hallux valgus osteotomy. Level of evidence III, retrospective comparative study.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Modified fourth-generation minimally invasive technique with a modified K-wire fixation technique for hallux valgus: a biomechanical and clinical study.BMC musculoskeletal disorders · 2026
- Risk factors for first metatarsal fracture in minimally invasive hallux valgus surgeryThe Bone & Joint Journal · 2026
- Determinants of Sagittal Alignment Following First Metatarsophalangeal Arthrodesis: The Influence of Native Anatomy, Fixation Construct, and Surgeon Experience.Journal of clinical medicine · 2026
- Minimally Invasive Distal Metatarsal Osteotomy: Does Screw Design, Number, and Position Matter?The Journal of foot and ankle surgery : official publication of the American College of Foot and Ankle Surgeons · 2026
- Radiological and Functional Outcomes of Fourth-Generation MIS Hallux Valgus Correction (META) in an Indian Population.Indian journal of orthopaedics · 2026
- Comparative Study of Akin Osteotomies with and Without Fixation in Open Hallux Valgus Correction Surgery: Retrospective Analysis of 200 Osteotomies.Journal of clinical medicine · 2026