Effect of Percutaneous Chevron and Akin Osteotomies on Measured First-Ray Joint Pressures: An Exploratory Cadaveric Study.
Agathe Yvinou, Fanny Delaigue, Maxime Sadoun, Benoît Rigolot, Thomas Bauer, Grégoire Rougereau
Orthopaedic Surgery Unit, Hospital La Cavale Blanche, Boulevard Tanguy Prigent, 29200 Brest, France. Electronic address: agathe.yvinou@gmail.com. · Orthopaedic Surgery Unit, Garches University Hospital, Assistance Publique - Hôpitaux de Paris, 104 boulevard Raymond Poincaré, 92380 Garches, France.
Key points
From the paper's conclusion- Under the tested conditions, this exploratory study did not detect a multiplicity-adjusted PECA-related change in measured intra-articular pressure at either joint. These findings do not establish equivalence, cartilage contact pressure, joint contact area, first-ray stability, or biomechanical safety.
Abstract
BACKGROUND: Percutaneous chevron and Akin osteotomies may alter first-ray mechanics, but their effects on pressure within the first tarsometatarsal and first metatarsophalangeal joints are unknown. PURPOSE: To assess immediate changes in measured intra-articular pressure within these joints after percutaneous chevron and Akin (PECA) osteotomies. STUDY DESIGN: Exploratory paired cadaveric biomechanical study. METHODS: Sixteen feet from 8 cadaveric donors were tested. Pressure transducer was inserted fluoroscopically into the first tarsometatarsal and first metatarsophalangeal joints. For each joint, hallux position, and loading condition, three consecutive pressure readings were obtained and averaged. Pre- versus post-PECA and rest-versus-manual-loading comparisons were analyzed using paired Wilcoxon signed-rank tests, with Holm adjustment across 40 comparisons. A donor-level sensitivity analysis was performed to address bilateral specimens. RESULTS: No PECA-related change in measured intra-articular pressure at either joint remained statistically significant after Holm adjustment for multiple comparisons. At the first tarsometatarsal joint, all mean paired pre- versus post-PECA changes had 95% confidence intervals that included zero. A donor-level sensitivity analysis accounting for bilateral feet did not alter the overall interpretation. CONCLUSION: Under the tested conditions, this exploratory study did not detect a multiplicity-adjusted PECA-related change in measured intra-articular pressure at either joint. These findings do not establish equivalence, cartilage contact pressure, joint contact area, first-ray stability, or biomechanical safety.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Computational biomechanical analysis of medial displacement calcaneal osteotomy placement and orientation.Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2026
- Endoscopic Plantar Partial Sesamoidectomy for the Management of Metatarsalgia of the First Metatarsal Head After Arthrodesis of the First Metatarsophalangeal Joint.Arthroscopy techniques · 2026
- Intraarticular calcaneal fractures: biomechanical analysis of two fixation constructs.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2026
- Biomechanical Effects of Distal Fragment Translation Guided by Target Postoperative Intermetatarsal Angle in Minimally Invasive Transverse Osteotomy for Hallux Valgus: A Patient-Specific Finite Element Study.Bioengineering (Basel, Switzerland) · 2026
- Using an instrumented hammer to predict the lateral hinge fracture in high tibial osteotomy: A cadaveric studyarXiv · 2026
- Changes in Vertical Mobility of the First Tarsometatarsal Joint During Gait After Combined Hallux Valgus Surgery Incorporating Proximal First Metatarsal Osteotomy.Journal of clinical medicine · 2026