Key points
From the paper's conclusion- The research group has measured window airing with own developed equipment and data management in 15 dwellings, in Umeå and South Sweden, over a year, with a time resolution of 1 minute and an angular resolution in the magnitude of 1 °.
Abstract
Window airing by the means of opening windows and doors by purpose by the occupant of a dwelling means, besides the extra ventilation it gives, that there will be an added energy use for heating the air that is exchanged from the outdoor to the indoor temperature. In energy simulations this is usually approximated rather roughly, for example to 4 kWh·m -2· a -1 in Sweden independent of where in Sweden it is. The research group has measured window airing with own developed equipment and data management in 15 dwellings, in Umeå and South Sweden, over a year, with a time resolution of 1 minute and an angular resolution in the magnitude of 1 °. This includes 53 windows or doors that were opened to at least some extent, some pivot hung windows and some side hung windows. The analysis of the measured data is presented in report however this paper presents an analysis of the energy use that is added is a result of the actually measured openings. This is done by combining the measurement results with theory of resulting airflow if the angle of a certain window is known. For very small angles, measurements were made of the resulting airflow by help of tracer gas technique. The result shows that the figure of 4 kWh·m -2· a -1 is plausible in some cases but the variation is large, between almost 0 and several times 4 kWh·m -2· a -1 . It also shows that the difference between just simulating the energy loss of a window with fixed indoor temperature over estimates the added energy use in a practical building due to the internal heat gains.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Residential Infiltration Performance Index for Saudi Villa and Apartment Archetypes: Cooling-Season Estimates Across 13 LocationsBuildings · 2026
- Impact of Airflow Modelling Approaches on Residential Building Energy Demand Under Different Climatic ConditionsBuildings · 2026
- Sensitivity of Heating Energy Demand to Indoor Temperature, Effective Air-Change Rate, and Climate: A TRNSYS Case Study Supporting Sustainable Operation of a Multi-Apartment BuildingSustainability · 2026
- Improving Airflow Network Models of Natural Ventilation: Geometry-Specific Pressures and Fluctuation CorrectionsarXiv · 2026
- Windows, fans, and solar shadings during summer and heatwave: Occupant behavior and potential for improvement in heat-mitigation practicesBuilding and Environment · 2025
- Feedback Effects of Air-Conditioning Anthropogenic Heat on Cooling Energy Consumption in Residential Buildings: A CFD–EnergyPlus Co-Simulation StudyBuildings · 2026