Feedback Effects of Air-Conditioning Anthropogenic Heat on Cooling Energy Consumption in Residential Buildings: A CFD–EnergyPlus Co-Simulation Study
Chengliang Fan, Jie Chen, Peng Yu
Guangdong University of Technology · Guangzhou University
Key points
From the paper's conclusion- Finally, EnergyPlus (V23.1.0) was employed as the building energy simulation software, with its microclimate coupling interface implemented via Python scripts to quantify cooling energy consumption variations across different building floors under ACAH influence.
Abstract
With global warming and accelerated urbanization, building air-conditioning (AC) releases more heat into the environment, exacerbating the urban heat island (UHI) effects and increasing building cooling energy consumption. Existing research has limited quantification of the impact of air-conditioning anthropogenic heat (ACAH) on the cooling energy consumption of different types. This study aims to explore the distribution characteristics of ACAH and its impact on residential building energy consumption. Firstly, typical residential buildings in the Pearl River Delta region were selected as a case study. Field experiments were conducted to measure temperature and humidity at 0.5 m, 1 m, 2 m, and 3 m from the outdoor unit, alongside ambient temperature and wind speed. Three grid densities were applied to verify the CFD model, with a prediction error of less than 0.3 °C at 0.5 m under a medium grid. The simulated temperature at 1 m from the outdoor unit under calm wind conditions was compared with field measurements to reveal the horizontal and vertical distribution characteristics of ACAH. Secondly, the effects of different building shapes, ambient temperatures, and wind speeds on the spatial distribution of ACAH were investigated. Finally, EnergyPlus (V23.1.0) was employed as the building energy simulation software, with its microclimate coupling interface implemented via Python scripts to quantify cooling energy consumption variations across different building floors under ACAH influence. Results indicated that ACAH exhibits significant horizontal non-uniformity, exerting the greatest impact within a 0.5 m radius (affected air temperature 4.3 °C higher than ambient). Vertically, localized heat accumulation occurs in the building’s central area, with air temperature 3.5 °C higher than at the bottom. Furthermore, compared to fixed meteorological conditions, the cooling energy consumption difference across floors considering ACAH reaches approximately 7.8%. This study provides accurate meteorological boundary conditions for building energy assessment and supports microclimate management in residential areas.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effects of anthropogenic heat on the urban wind-thermal environment in typical residential neighborhoods in Nanjing, ChinaEnergy and Built Environment · 2026
- Multi-Objective Evaluation of Recirculating Air-Conditioning Operation in University Dormitories: Thermal Comfort, CO2 Exposure, and Energy UseBuildings · 2026
- Artificial Intelligence-Driven Cooling Load Forecasts in Dense Urban EnvironmentsASME Journal of Engineering for Sustainable Buildings and Cities · 2026
- Role of HVAC in building energy consumption: a critical reviewJournal of Thermal Analysis and Calorimetry · 2026
- Influence of Local Wind Pressure Coefficients Based on Height-Varying Reference Wind Speed on Building Energy Performance in a Dense Urban EnvironmentSustainability · 2026
- Quantifying the Thermal and Energy Impacts of Air Infiltration in a Hot-Humid Educational Building: A Sensitivity Analysis Using a Field-Evaluated EnergyPlus ModelBuildings · 2026