Impacts of air conditioner operation behavior on indoor CO2 concentration and indoor air quality in high-rise apartment: case study in Hanoi
Nguyen Thi An Anh, Pham Thi Hai Ha, Nguyen Thi Khanh Phuong, Dirk Schwede
Key points
From the paper's conclusion- This study examines how occupant air-conditioner operation behavior influences indoor CO 2 concentration and indoor air quality in modern high-rise apartments.
Abstract
This study examines how occupant air-conditioner operation behavior influences indoor CO 2 concentration and indoor air quality in modern high-rise apartments. A comprehensive, full-year measurement and household survey were conducted in Hanoi within the framework of the CAMaRSEC project. The dataset includes 49 occupied apartments, each monitored in a living room and a bedroom yielding a high-resolution record of indoor CO 2 levels, thermal conditions, and AC patterns. Linear Mixed-Effects Models and building physics-controlled pairs were employed to quantify how behavior-driven ventilation affects indoor CO2 dynamics. Results show that active cooling behavior, typically involving AC operation in airtight conditions, is associated with a significant CO2 increase higher than non-AC modes. In bedrooms, CO2 concentrations rose significantly during AC use, whereas living rooms experienced a smaller increase due to architectural characteristics. The study further identifies an inverse correlation between indoor temperature and CO2 levels during non-AC periods. Analysis of recovery events reveals that the median time required to return to baseline CO2 levels high. The findings confirm that occupant behavior, specifically the “airtightness habit” to preserve thermal storage, is a more dominant driver of indoor air quality than building technical specifications. The study proposes occupant-centered mitigation measures, including specialized ventilation strategies for confined spaces and the integration of real-time CO2 monitoring with visual feedback. These strategies collectively support the reduction of household CO 2 emissions while improving indoor living conditions in modern apartment buildings.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Predicting multiple indoor air quality parameters from spatial factors, occupant behaviours, and external conditions in single-zone urban residential units: a case study in BangkokAir Quality Atmosphere & Health · 2026
- Impact of Occupant Behavior on Indoor Air Quality in Small Single-Person Households: A Field Study Using Low-Cost SensorsBuildings · 2026
- Attribution of Elevated Indoor CO2 Levels to Household Energy ConsumptionACS ES&T Air · 2026
- Multi-Objective Evaluation of Recirculating Air-Conditioning Operation in University Dormitories: Thermal Comfort, CO2 Exposure, and Energy UseBuildings · 2026
- Desk‐Level CO 2 Sensing for Monitoring Occupancy and Indoor Environmental QualityIndoor Air · 2026
- Intelligent Ventilation and Indoor Air Quality: State of the Art Review (2017–2025)Buildings · 2025