Mesoporous silica-supported Co-doped MnO2 nanozyme-mediated signal amplification for lateral flow immunoassay of the AMI biomarker cTnI.
Haosen Fan, Shuo Tian, Shun Wang, Mengke Wang, Lizeng Gao
Nanozyme Laboratory in Zhongyuan, Henan Academy of Innovations in Medical Science, Zhengzhou, Henan, 451163, China. wangmengke19@163.com. · Center for Medical Experiment, The Second Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan, 450014, China. wshun155@163.com.
Key points
From the paper's conclusion- Nanozyme-mediated lateral flow immunoassay (NLFIA) is a widely adopted technique for biomarker detection owing to its catalytic signal amplification capability.
Abstract
Acute myocardial infarction (AMI) is a fatal complication of coronary heart disease, and rapid testing for the biomarker, cardiac troponin I (cTnI), is essential for its early diagnosis. Nanozyme-mediated lateral flow immunoassay (NLFIA) is a widely adopted technique for biomarker detection owing to its catalytic signal amplification capability. Conventional peroxidase (POD)-like nanozyme-based NLFIA requires H2O2 and restricts on-site use, while NLFIA based on oxidase (OXD)-like nanozymes avoids exogenous H2O2. Although some OXD-like nanozyme-based NLFIA systems have been reported, few have been exploited for highly sensitive clinical protein biomarker detection. This field faces two major problems: the poor chromatographic mobility and low activity of nanozymes. Herein, a mesoporous silica (mSiO2)-supported cobalt-doped manganese dioxide (Co-MnO2@mSiO2) nanozyme was successfully synthesized. Mesoporous silica (mSiO2) is adopted as a carrier to enhance the mobility of the nanozyme. The immobilization of MnO2 onto mSiO2 yields an outstanding OXD-mimicking nanozyme (MnO2@mSiO2). Moreover, through a synergistic metal strategy, Co-doped MnO2@mSiO2 (Co-MnO2@mSiO2) was screened and found to possess the optimal OXD-like activity of 6500 U g-1. Benefiting from its excellent colorimetric functionality, robust OXD-mimicking activity, and favorable lateral flow mobility, Co-MnO2@mSiO2 was employed as an NLFIA probe for the sensitive detection of cTnI. The limit of detection (LOD) for cTnI in the colorimetric mode is 0.245 ng mL-1. Additionally, Co-MnO2@mSiO2 significantly improves the detection sensitivity by oxidizing 3,3',5,5'-tetramethylbenzidine, and the LOD in the catalytic enhancement mode is 0.011 ng mL-1. The successful application of this method to human serum detection highlights its potential as a powerful testing tool for AMI diagnosis.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The Au-CeO2 Nanozyme with Enhanced Peroxidase-like Activity for Highly Sensitive Ratiometric Colorimetric Detection of Nitrite.Foods (Basel, Switzerland) · 2026
- Decoupled Signal Transduction via a Non-Copper Laccase Mimic for CRISPR-Based Electrochemical Detection of Hepatocellular Carcinoma.Analytical chemistry · 2026
- Rapid and ultrasensitive activity detection of α-amylase based on γ-cyclodextrin crosslinked aminated Fe-Ni bimetallic MOF nanozyme.Journal of pharmaceutical and biomedical analysis · 2026
- Platinum-based Nanozyme screening coupled with ISAR-generated pyrophosphate for dual-mode detection of cardiovascular disease-associated miRNA-21.Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2026
- Oxygen-vacancy-rich amorphous MnO2@MOF-808 nanozyme for dual-mode colorimetric and smartphone-assisted determination of Sr2+ and H2O2.Talanta · 2026
- CoMn Nanosheets Mediate Water-Driven Luminol Electrochemiluminescence via Coupled Electrocatalysis and Nanozyme Activity for BiosensingAnalytical Chemistry · 2026