Platinum-based Nanozyme screening coupled with ISAR-generated pyrophosphate for dual-mode detection of cardiovascular disease-associated miRNA-21.
Minghui Chen, Jie Zhu, Lingyue Xu, Wenbei Liu, Diya Qi
Department of Cardiology, The Affiliated Xuzhou Municipal Hospital of Xuzhou Medical University, Xuzhou First People's Hospital, Xuzhou, 221100, China; School of Medical Imaging, Xuzhou Medical University, Xuzhou, 221006, China. · School of Medical Imaging, Xuzhou Medical University, Xuzhou, 221006, China; State Key Laboratory of Radiation Medicine and Protection, School of Radiation Medicine and Protection, Soochow University, Suzhou, 215123, China.
Key points
From the paper's conclusion- This dual-mode platform provides a rapid, sensitive, and reliable approach for miRNA-21 detection, demonstrating potential utility for CVD-associated biomarker analysis and further clinical investigation.
Abstract
Early assessment of cardiovascular disease (CVD)-associated molecular alterations may provide valuable information for disease monitoring and clinical evaluation. MicroRNA-21 (miRNA-21) is involved in multiple cardiovascular pathological processes and has been widely investigated as a CVD-associated circulating biomarker. Rationally modulating the activity of platinum-based nanozymes can expand sensing strategies and improve the performance of miRNA-21 detection. Herein, four platinum-based nanozymes are synthesized via a one-step reduction method and systematically evaluate their peroxidase (POD)-like catalytic activities. Among them, the NiPt nanozyme exhibits a favorable apparent peroxidase-like activity under an equal mass concentration, with the lowest Michaelis-Menten constant of 0.462 mM. Then, a colorimetric and fluorescent dual-mode biosensor is developed for the rapid and sensitive detection of miRNA-21 via NiPt nanozyme couple with the target-triggered invading stacking primer-based amplification reaction (ISAR). Sequence-specific hybridization between miRNA-21 and the designed hairpin DNA probe initiates ISAR and generates pyrophosphate (PPi), which suppresses the peroxidase-like activity of NiPt NPs and enables fast, instrument-free, and colorimetric qualitative detection of miRNA-21 at 5 × 10-11 M. Simultaneously, the Cy5 fluorescence signal exhibits sensitive quantitative detection of miRNA-21 with a limit of detection (LOD) of 2.27 × 10-13 M over a linear range of 10-12-10-9 M (R2 = 0.971). The biosensor demonstrated high selectivity toward miRNA-21 against representative interfering miRNA sequences and showed consistency with qRT-PCR in clinical serum samples from heart failure patients and healthy individuals. This dual-mode platform provides a rapid, sensitive, and reliable approach for miRNA-21 detection, demonstrating potential utility for CVD-associated biomarker analysis and further clinical investigation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Nanozyme‐Driven Next‐Generation miRNA BiosensingWiley Interdisciplinary Reviews Nanomedicine and Nanobiotechnology · 2026
- Bifunctional CuPt Nanoclusters and DSN-Mediated Target Recycling Enabled Dual-Mode OPECT/Colorimetric Biosensing for Ultrasensitive and Wide-Range Detection of miRNA-21.Analytical chemistry · 2026
- Ce-doped BiF3@Pt nanocatalyst enhanced CHA-based electrochemical biosensor for sub-femtomolar detection of miRNA-21.Bioelectrochemistry (Amsterdam, Netherlands) · 2026
- Mesoporous silica-supported Co-doped MnO2 nanozyme-mediated signal amplification for lateral flow immunoassay of the AMI biomarker cTnI.Journal of materials chemistry. B · 2026
- 2D Ti3C2Tx MXene nanozymes based electrochemical MicroRNA biosensor and application to early diagnosis of sepsis-associated acute kidney injuryMicrochimica Acta · 2025
- Unlocking Ultrasensitive MicroRNA-21 Signals with a Dual-Output Strand Displacement BiosensorAnalytical Chemistry · 2026