The Au-CeO2 Nanozyme with Enhanced Peroxidase-like Activity for Highly Sensitive Ratiometric Colorimetric Detection of Nitrite.
Luyu Chen, Wenting Lu, Chunyan Sun, Yingrui Zhang, Jicai Cai, Jiaqi Chen, Linna Du, Jiajun Hu,
College of Advanced Materials Engineering, Jiaxing Nanhu University, Jiaxing 314001, China. · Zhejiang Huayou Cobalt Co., Ltd., Jiaxing 314599, China.
Key points
From the paper's conclusion- Herein, we report a ratiometric assay based on Au-loaded mesoporous CeO2 (Au–CeO2) nanozymes with enhanced peroxidase-like activity for highly sensitive nitrite detection.
Abstract
Nitrite (NO2-) is a common food additive but it poses serious health risks due to its potential to form carcinogenic N-nitrosamines. Rapid and sensitive detection of nitrite in food matrices remains a critical need. Herein, we report a ratiometric assay based on Au-loaded mesoporous CeO2 (Au-CeO2) nanozymes with enhanced peroxidase-like activity for highly sensitive nitrite detection. The Au-CeO2 nanozyme was synthesized via a facile thermal decomposition and reduction method. Au-CeO2 nanozyme exhibited a higher Ce3+/Ce4+ ratio (from 25:75 to 31:69) and increased oxygen vacancy density (from 22.4% to 31.2%) compared to pristine CeO2. Meanwhile, the mesoporous structure effectively enhances the interaction between catalytic substrates and the active sites of nanozymes. The mesoporous structure is favorable for substrate accessibility to the active sites, which may contribute to the enhanced peroxidase-like catalytic performance. The nanozyme efficiently catalyzed the oxidation of 3,3',5,5'-tetramethylbenzidine (TMB) to oxTMB, producing a strong absorbance at 652 nm. Upon the addition of nitrite, diazotization of oxTMB occurred, leading to a decreased signal at 652 nm and a new absorbance peak at 445 nm. This ratiometric response (A652/A445) enabled sensitive detection of NO2- in the range of 1-200 μM with a detection limit of 0.43 μM. The ratiometric colorimetric assay demonstrated excellent selectivity and was successfully applied to real food samples with a satisfactory recovery (95.4-106.6%, RSD < 2.73%). The ratiometric colorimetric method provides a novel analytical strategy for environmental and food safety monitoring, offering high sensitivity, high accuracy, and excellent reliability.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A ratiometric nanozyme sensor with smartphone-assisted visual detection for rapid nitrite detection in meat products based on Mn2O3/MnNiO3 composite microspheres.Mikrochimica acta · 2026
- CuCo-N-C nanozyme-mediated hydrogel colorimetric platform: dual-reading modes of ratiometry and smartphone for nitrite detection.Analytical methods : advancing methods and applications · 2026
- Bifunctional Carbon Dot Nanozymes for Ratiometric Optical, Photothermal, and Smartphone-Assisted Multimodal Detection of NitriteAnalytical Chemistry · 2026
- Mesoporous silica-supported Co-doped MnO2 nanozyme-mediated signal amplification for lateral flow immunoassay of the AMI biomarker cTnI.Journal of materials chemistry. B · 2026
- Thermal Modulation of Cerium-Based Nanozyme Activity for Colorimetric Detection of Ascorbic Acid.Langmuir : the ACS journal of surfaces and colloids · 2026
- Ce and Ni Supported on N-Doped Carbon as a Diatomic Nanozyme and a Colorimetric Sensor for the Detection of ArseniteACS Applied Nano Materials · 2026