Stopping, opening, and redirecting fluid flow in paper-based microfluidic devices using thermo-responsive gelatin valves.
Abdolali Mehrjou, Seyed Hamid Safiabadi Tali, Mohsen Ghiasi Tarzi, Zubi Sadiq, Sana Jahanshahi-Anbuhi
Department of Chemical and Materials Engineering, Gina Cody School of Engineering, Concordia University Montréal Québec H4B 1R6 Canada sana.anbuhi@concordia.ca.
Key points
From the paper's conclusion- These findings establish gelatin as a tunable material for timed fluid control in paper microfluidic devices.
Abstract
The advancement of microfluidic paper-based analytical devices (µPADs) toward complex biochemical assays is hindered by the lack of reliable, low-cost fluid-control strategies capable of providing defined sealing and actuation times. The environmental sensitivity of passive barriers depends on their material composition and formulation, whereas many active valves require comparatively complex fabrication. This work introduces a thermo-responsive gelatin valve as a simple, inexpensive, and biocompatible approach to fluid control. Valve performance was optimized by varying gelatin concentration, cooling conditions, storage duration, and actuation temperature. A concentration of 30 mg mL-1 provided the most suitable balance between closed-state retention and thermal responsiveness. Porometry and contact-angle measurements indicated that the gelatin-treated region reduced accessible capillary pathways and exhibited a water contact angle of approximately 99°, thereby preventing flow at room temperature. Under controlled heating at 40 °C, the optimized valve opened in approximately 20 s. The valve was integrated into a paper-based acetylcholinesterase inhibition assay for malathion. A single-shot design reduced the number of liquid-addition steps by combining sample delivery and incubation in one operation. The calculated limit of detection (LOD) was 0.24 µM, below the drinking-water guideline value of approximately 0.88 µM. A 0.5 µM malathion spike in St. Lawrence River water produced a recovery of 86.1 ± 3.2%. The device is presented as a proof-of-concept screening platform, with further matrix validation required before regulatory drinking-water analysis. These findings establish gelatin as a tunable material for timed fluid control in paper microfluidic devices.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Autonomous paper valves using PDMS vacuum pumps as actuators for colorimetric chrono-sampling.Lab on a chip · 2026
- High‐Performance Light‐Triggered Hydrogel Microvalve with Rigid Framework Structure for MicrofluidicsAdvanced Optical Materials · 2026
- Controlled Movement of Soft Actuators using Multi‐Responsive Microgel Arrays and Microcirculatory SystemsAdvanced Functional Materials · 2025
- Interface-Tailored Hydrogel Microneedle Array Patch with Laser-Engraved Graphene Electrodes for Continual In Vivo Interstitial Fluid MonitoringAnalytical Chemistry · 2026
- Smartphone-based flow-controlled μPAD for automated nitrite determination.Lab on a chip · 2026
- Development of an immersion-type hydrogel-integrated microfluidic glass fiber-based analytical device and its application to smartphone-assisted glucose colorimetric assay.Talanta · 2026