Smartphone-based flow-controlled μPAD for automated nitrite determination.
Pablo Escobedo, Maria Angustias Torres-Molina, Isidoro Ruiz-García, Miguel A Carvajal, Miguel M Erenas, Antonio Martínez-Olmos, Isabel M Pérez de Vargas Sansalvador, Luis F Capitán-Vallvey,
PRIMELab, Electronic and Chemical sensing solutions (ECsens), CITIC-UGR, iMUDS, Department of Electronics and Computer Technology, University of Granada, 18071, Granada, Spain. pabloescobedo@ugr.es. · PRIMELab, Electronic and Chemical sensing solutions (ECsens), Department of Analytical Chemistry, University of Granada, 18071, Granada, Spain.
Key points
From the paper's conclusion- We report a smartphone-based microfluidic platform for automated nitrite determination using a paper colourimetric assay.
Abstract
We report a smartphone-based microfluidic platform for automated nitrite determination using a paper colourimetric assay. The system combines a V-shaped microfluidic paper-based analytical device (μPAD), a wireless electronic module for capacitive flow monitoring and thermal actuation, and a custom Android application that coordinates the measurement sequence and processes the captured image. Fluid arrival at the sensing zone is identified from changes in capacitance, which trigger the heating step required to collapse a NIPAM-based hydrogel reservoir and release sulfanilic acid from the hydrogel reservoir. Images are acquired under ambient lighting conditions and analysed by an image-processing algorithm that includes circle detection, saturation-value (SV)-based pixel selection, and colour correction using in-frame black and white references. Calibration with standard nitrite solutions showed that the platform achieved a limit of detection (LOD) of 7.63 × 10-6 M (0.35 mg L-1 as NO2-) after colour correction, improving by about 17% with respect to the uncorrected response. The platform also showed good repeatability (CV < 6% at 10-4 M) and consistent behaviour when tested with two different smartphones and several lighting conditions. Analysis of tap water and marine samples gave results in agreement with the reference method at the 95% confidence level. The platform combines automated fluid handling, thermally triggered reagent release, and adaptive image-based quantification in a portable format for nitrite analysis outside the laboratory.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Development of a microfluidic paper-based analytical device (μPAD) for detection of urea, nitrite, and starch adulteration in milk with smartphone app assisted detectionInnovative Food Science & Emerging Technologies · 2026
- A 3D Microfluidic Paper-Based Analytical Device with Smartphone-Based Colorimetric Readout for Phosphate SensingSensors · 2026
- Barcode-based paper analytical device for point-of-care chloride detection with user-independent readout.The Analyst · 2026
- Self-Calibrating Ratiometric Colorimetric Microfluidic Paper-Based Analytical Device for Visual Quantification of Hypoxanthine.Analytical chemistry · 2026
- Geometry-driven miniaturization of a microfluidic paper-based analytical device for reagent-efficient colorimetric detection of dopamine.Biomedical microdevices · 2026
- A Laminated Microfluidic Paper-Based Analytical Device Based on Image Analysis Using Optimized Color Space for Simultaneous Multiplexed Quantification of Chemical Water Quality Parameters.Analytical chemistry · 2026