A stabilized single-reagent TMB method for free chlorine monitoring in drinking water-related matrices.
Hao Zhang
Onestep Technologies Inc., Vancouver, Canada. zhang@onestep-technologies.com.
Key points
From the paper's conclusion- Together, these results show close agreement with routine DPD measurements across the evaluated drinking water-related matrices and provide a quantitative basis for further translation into a compact monitoring platform.
Abstract
Continuous free chlorine monitoring supports drinking water and treated water management, but practical implementation depends on analytical performance as well as reagent handling and fluidic simplicity. This short communication evaluates a stabilized single-reagent tetramethylbenzidine (TMB) method designed as a measurement layer for simplified online monitoring. Quantitative comparison used a controlled benchtop fixed-time absorbance-at-650-nm (A650) readout at 30 s. The dataset comprised 32 paired measurements, including 20 tap-water or finished-water samples and 12 controlled matrix-concentration conditions spanning three defined mineral-background matrices evaluated at four free-chlorine levels each. TMB and N,N-diethyl-p-phenylenediamine (DPD) comparator measurements were performed within 5 min and in triplicate. Deming regression yielded a slope of 0.985 and an intercept of 0.007 mg L⁻1 as Cl2. The mean paired difference (TMB-DPD) was + 0.001 mg L⁻1 and the mean absolute difference was 0.013 mg L⁻1. Precision assessed from the triplicate TMB readings gave a median RSD of 2.4% and a mean RSD of 3.6%. Sealed storage observations further supported the reagent-handling rationale for a stabilized single-reagent format. Together, these results show close agreement with routine DPD measurements across the evaluated drinking water-related matrices and provide a quantitative basis for further translation into a compact monitoring platform.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A multivariate approach to amperometric free chlorine monitoring: calibration, interference compensation, and application in water distribution systems.RSC advances · 2026
- Multicenter evaluation of analytical performance and onboard stability of Mindray 10 concentrated biochemical reagentsJournal of Laboratory Medicine · 2026
- A multi-angle continuous-flow injection analysis turbidimetric method for the determination of diphenhydramine hydrochloride.Royal Society open science · 2026
- A barcode-enabled distance-based paper sensor using silver chloranilate for semi-quantitative determination of chloride in various water sources.Analytical methods : advancing methods and applications · 2026
- Capillary dried plasma microsampling: A novel approach for therapeutic drug monitoring of tyrosine kinase inhibitors in chronic myeloid leukemia patients by UPLC-MS/MS.Journal of pharmaceutical and biomedical analysis · 2026
- Innovative Technologies for the Online Monitoring of Chloroform in Water by MicroNIR/Chemometrics SystemsAnalytica · 2026