Electrochemical differentiation of native-denatured hemoglobin using a same-metal PCB-based three-electrode system.
Churun Jauharoh Al Aryachiyah, Mohammad Nofil, Akmal Fathurrahman Zullkifli, Prince Nishchal Narayanaswamy Elumalai, Chethan C Thimmarayappa, Sara Talebi, Mitsumasa Iwamoto, Vengadesh Periasamy
Low Dimensional Materials Research Centre (LDMRC), Department of Physics, Faculty of Science, Universiti Malaya Kuala Lumpur 50603 Malaysia vengadeshp@um.edu.my. · eProfiler Solutions Malaysia Sdn Bhd 15-26, Pacific 63@PJ Centre, No. 5, Seks 13, Jln 13/6 Petaling Jaya 46200 Selangor Malaysia.
Key points
From the paper's conclusion- Interestingly, despite the absence of dissimilar electrode materials, the current PCB-based same-metal three-electrode (PCB-3T) sensor successfully produced characteristic Hb electrochemical profiles.
Abstract
Denaturation statistically decreases a protein's structural stability and alters its reactivity, particularly in its redox reactions. One such protein is the redox-active hemoglobin (Hb) molecule, which is among the most extensively studied due to its importance in respiration. To investigate its redox activity, the standard electrochemical sensing method using a three-electrode platform has been widely employed. In this work, however, an unconventional approach was used whereby a same-metal (gold) three-electrode sensor was utilized. Interestingly, despite the absence of dissimilar electrode materials, the current PCB-based same-metal three-electrode (PCB-3T) sensor successfully produced characteristic Hb electrochemical profiles. In phosphate-buffered saline, closely spaced anodic and cathodic peak potentials were observed, indicating enhanced redox reversibility; an outcome that is difficult to achieve in in vitro studies of conventional systems without extensive surface modification. Additionally, a cathodic potential peak was detected when Hb was dissolved in ultrapure H2O, consistent with previous in vivo research. The miniaturized architecture of PCB-3T enables microliter-scale analysis with minimal activation cycles, making it suitable for characterizing unstable proteins, such as denatured Hb. Cyclic voltammetry (CV) results indicated that denatured Hb exhibited irregular peak potential shifts and higher peak currents than native Hb; consequently, electrochemical impedance spectroscopy revealed differences between native and denatured Hb in Nyquist and Bode plots. p-values of 0.003 and 0.02 (α = 0.05, n = 5) were obtained for CV anodic potential differentiation, indicating improved resolution, and the reproducibility offers potential for further protein electrochemistry studies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Defining redox-driven conformational change in Allochromatium vinosum thiosulfate dehydrogenase (TsdA).Journal of biological inorganic chemistry : JBIC : a publication of the Society of Biological Inorganic Chemistry · 2026
- Quantifying the Sequence-Dependent Kinetic Protection of Reduced Heme in Peptide Amphiphile Nanofibers.The journal of physical chemistry. B · 2026
- A miniaturized drop-based three-electrode system for sensitive electrochemical determination of azathioprine using pencil graphiteScientific Reports · 2026
- Comparative Electrochemical Behavior of Three Pilins From Acidithiobacillus thiooxidans at a Copper ElectrodeElectroanalysis · 2026
- Self-assembled perylene diimide/CuO p-n heterojunction-enhanced photoelectrochemical platform for sensitive dopamine detection.Mikrochimica acta · 2026
- A thread-based microfluidic electrochemical platform for whole-blood protein sensing using endogenous uric acid as a redox mediator.Lab on a chip · 2026