Electrochemical sensors based on track-etched membranes for rare earth and heavy metal ion detection.
Nurdaulet Zhumanazar, Arman B Yeszhanov, Galina B Melnikova, Ainash T Zhumazhanova, Indira B Muslimova, Sergei A Chizhik, Abzal A Taltenov, Ilya V Korolkov
The Institute of Nuclear Physics ARKAE Ibragimov Str., 1 050032 Almaty Kazakhstan i.korolkov@inp.kz. · A.V. Luikov Heat and Mass Transfer Institute of The National Academy of Sciences of Belarus P. Brovki Str., 15 220072 Minsk Belarus.
Key points
From the paper's conclusion- The results indicate a significant improvement in electrochemical performance due to the grafted PET TeMs-g-p(NHMA-co-HEMA) structure and the developed sensor demonstrates high applicability and stable performance for the detection of rare earth and heavy metal ions in tap water as well.
Abstract
Electrochemical sensors were developed using track-etched polyethyleneterephthalate (PET TeMs) membranes modified by UV-initiated graft copolymerization to produce PET TeMs-g-p(NHMA-co-HEMA). The modification process, structural features and physicochemical properties of the resulting membranes were comprehensively characterized using scanning electron microscopy (SEM), thermogravimetric analysis (TGA), Fourier transform infrared spectroscopy (FTIR), Energy-Dispersive X-ray spectroscopy (EDX), UV-visible spectrophotometry (colorimetric method), gas permeability measurements and contact angle analysis. Optimal grafting conditions were achieved at a monomer concentration of 10% (NHMA : HEMA = 70 : 30), UV irradiation time of 60 min and UV lamp distance of 10 cm at a temperature of 38-40 °C. The modified membranes were subsequently used in an electrode system to determine Eu3+, Gd3+, La3+, Ni2+ and Pb2+ ions using square-wave anodic stripping voltammetry (SW-ASV). The sensors were evaluated over this concentration range of 1 × 10-7-1 × 10-4 for Ni2+, 0.5 × 10-7-1 × 10-5 M for Pb2+, 0.5 × 10-6-5 × 10-5 M for Eu3+, 0.5 × 10-6-0.5 × 10-4 M for Gd3+, and 1 × 10-6-1 × 10-4 M for La3+, with detection limits of 8.5 × 10-7 M for Eu3+ (R 2 = 0.96), 6.3 × 10-6 M for Gd3+ (R 2 = 0.975), 2.51 × 10-6 M for La3+ (R 2 = 0.96), 8.7 × 10-7 M for Pb2+ (R 2 = 0.98), and 7.4 × 10-6 M for Ni2+ (R 2 = 0.98). The results indicate a significant improvement in electrochemical performance due to the grafted PET TeMs-g-p(NHMA-co-HEMA) structure and the developed sensor demonstrates high applicability and stable performance for the detection of rare earth and heavy metal ions in tap water as well.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Detection of Cd2+ and Pb2+ in egg yolk and maize samples by a novel SDA/MWCNTs-based electrochemical sensor.RSC advances · 2026
- Impact of alginate microgels on the performance of hybrid PSF/PVP/graphite electrodes for sensitive heavy-metal analysis.Talanta · 2026
- Preparation of PVDF-g-PNIPAM Ultrafiltration Membrane by Gamma Ray Irradiation and its Separation Effect on Mg2+ and Li+High Energy Chemistry · 2026
- Preparation of PES-g-PMAA@Ca Ultrafiltration Membrane via Using Gamma Ray Irradiation and its Impact on the Treatment of Wastewater with High SalinityHigh Energy Chemistry · 2026
- Novel polyelectrolyte functionalized mesoporous silica for sustainable and ultraselective adsorption of Re(VII) and 99Tc(VII) remediation.Journal of hazardous materials · 2026
- Adsorption of REEs from aqueous solutions using modified polystyrene- di (2-ethylhexyl) phosphoric acid electrospun nanofibersSurfaces and Interfaces · 2026