Talanta

Impact of alginate microgels on the performance of hybrid PSF/PVP/graphite electrodes for sensitive heavy-metal analysis.

Claudia D Padilla, Eduardo A Takara, María L Scala-Benuzzi, María A Ferroni-Martini, Nelio A Ochoa, Sirley V Pereira, Franco A Bertolino, Germán A Messina

INQUISAL, Departamento de Química, Facultad de Química, Bioquímica y Farmacia, Universidad Nacional de San Luis, Av. Ejército de los Andes 950, D5700BWS, San Luis, Argentina. · Instituto de Física Aplicada (INFAP), Departamento de Química, Universidad Nacional de San Luis, CONICET, Av. Ejército de los Andes 950, D 5700 BWS, San Luis, Argentina. Electronic address: eatakara@gmail.com.

Key points

From the paper's conclusion
  • The obtained results demonstrate that the alginate microgel incorporation into a polysulfone-based conductive composite represents a simple interfacial engineering strategy to promote metal accumulation and improve analytical performance, providing a promising low-cost platform for heavy-metal determination in water samples.

Abstract

A hybrid electrochemical sensing platform based on an alginate microgel/polysulfone/polyvinylpyrrolidone/graphite composite was developed for the sensitive detection of heavy metals in water samples. Incorporating alginate microgels within the polysulfone-based matrix introduces hydrophilic domains that improve wettability and electrolyte accessibility, thereby favoring metal-ion accumulation at the electrode interface. Structural and electrochemical characterization was performed by scanning electron microscopy (SEM), Fourier-transform infrared spectroscopy (FTIR), and electrochemical impedance spectroscopy (EIS), complemented by contact-angle and swelling measurements. These analyses supported the incorporation of micrometer-sized alginate domains and their contribution to the interfacial properties of the polymer-graphite matrix. Heavy-metal detection was performed by anodic stripping voltammetry (ASV), showing good linearity over the concentration range of 0.1-50 μg L-1, with correlation coefficients higher than 0.995 for Cd2+, Pb2+, and Cu2+. The obtained limits of detection were 0.42 μg L-1 for Cd2+, 0.23 μg L-1 for Pb2+, and 0.22 μg L-1 for Cu2+. The sensor demonstrated good inter-electrode reproducibility, selectivity in the presence of common interfering ions, and stable analytical performance. The obtained results demonstrate that the alginate microgel incorporation into a polysulfone-based conductive composite represents a simple interfacial engineering strategy to promote metal accumulation and improve analytical performance, providing a promising low-cost platform for heavy-metal determination in water samples.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers