Investigation of a surface decorated Ag-MnO2@MGCN nanointerface towards membrane-free electrochemical Na+ ion sensing in sweat.
Nikita J Patil, Ganesh Kumar Mani, Kamalakannan Kailasam, Murali Rangarajan, Parthasarathy Srinivasan
Center of Excellence in NanoTechnology & Advanced Materials (CENTAM), Department of Electronics and Communication Engineering, Amrita School of Engineering, Amrita Vishwa Vidyapeetham Chennai Tamil Nadu 601103 India s_parthasarathy@ch.amrita.edu. · Department of Physics, Korea Advanced Institute of Science and Technology Korea.
Key points
From the paper's conclusion- These findings demonstrate the potential of the developed Ag-MnO2@MGCN nanointerface for the future development of membrane-free electrochemical sensors for Na+ detection in sweat.
Abstract
Noninvasive continuous electrolyte monitoring, including Na+ ion levels in sweat, is essential for real-time physiological assessment. The changes in sweat Na+ ion levels reflect underlying physiological conditions and might be used as a potential biomarker for electrolyte imbalances. In this work, we report an electrochemical Na+ ion switch based on a surface-anchored Ag-MnO2@mesoporous graphitic carbon nitride (MGCN) nanointerface. The results of morphological analysis revealed a hierarchical architecture consisting of MnO2 nanorods uniformly anchored to MGCN nanosheets and decorated with Ag nanoparticles that form a highly conductive and electroactive platform. Electrochemical analysis showed distinct oxidation and reduction peaks at 0.25 V and 0.08 V, respectively, indicating strong redox activity and efficient charge transfer upon interaction with Na+ ions. The Ag-MnO2@MGCN sensor showed a broad linear range from 0.1 to 150 mM, with a LOD of 0.06 mM, and a sensitivity of 9.62 µA mM-1 cm-2. The sensor also demonstrated excellent repeatability, stability and high recovery values ranging from 96.46% to 101.2% in artificial sweat samples, confirming its analytical reliability. The sensing mechanism is explained via the intercalation-deintercalation behaviour of Na+ ions within the MnO2 framework of Ag-MnO2@MGCN, while Ag nanoparticles and MGCN synergistically enhance charge transfer. These findings demonstrate the potential of the developed Ag-MnO2@MGCN nanointerface for the future development of membrane-free electrochemical sensors for Na+ detection in sweat.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Tunnel-structured Na0.44MnO2 battery cathode as a label-free amperometric platform for non-invasive sodium ion detection in salivaElectrochimica Acta · 2026
- Ti3C2T x MXene-Enhanced Paper-Based Ion-Selective Electrodes for Sweat Sodium Monitoring.ACS measurement science au · 2026
- A wearable sensor integrating a MXene-PLL-GOx-modified electrode and a Janus nanofibrous membrane for electrochemical monitoring of sweat glucose.Talanta · 2026
- Interface-Programmed Growth of High-Aspect-Ratio 1D Ni-MOF Nanofibers on MXene for Wearable Enzyme-Free Glucose Sensing.ACS applied materials & interfaces · 2026
- Plasmon-enhanced molecularly imprinted photoelectrochemical sensor for non-invasive lactate monitoring in sweat.Chemical communications (Cambridge, England) · 2026
- Engineered AuNPs/fMWCNT Nanocomposite Electrodes for High‐Sensitivity Methylglyoxal Sensing in Saliva and Sweat for Non‐Invasive Diabetes MonitoringAdvanced Healthcare Materials · 2026