Self-Calibrating Ratiometric Colorimetric Microfluidic Paper-Based Analytical Device for Visual Quantification of Hypoxanthine.
Rui Wang, Ji Qi, Jie Shao, Qi Zhang, Mengfei Zhu, Zhong Zhang, Lingxin Chen, Xiaokun Wang
College of Biological Engineering, Qingdao University of Science and Technology, Qingdao266042, China. · Shandong Key Laboratory of Coastal Zone Environmental Processes and Ecological Security, Shandong Engineering Research Center for Coastal Zone Ecological & Environmental Monitoring Technologies and Equipment, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai264003, China.
Key points
From the paper's conclusion- This dual error-control strategy establishes a general framework for robust quantitative paper-based colorimetric sensing.
Abstract
Existing self-calibrating strategies improve quantitative paper-based colorimetry by correcting imaging variations, yet their analytical reliability remains limited because heterogeneous sensing interfaces introduce errors that cannot be compensated by internal-reference calibration alone. Herein, we present a self-calibrating ratiometric microfluidic paper-based analytical devices (μPADs) based on a dual error-control strategy that integrates interface homogenization with internal-reference correction for portable hypoxanthine (Hx) quantification, an important early freshness indicator of aquatic products. A sol-gel/chitosan (Sol-Gel/CS) hybrid network uniformly immobilizes MnO2 nanoflowers (NFs), suppressing coffee-ring formation while improving reagent stability, catalytic activity, and color uniformity. Xanthine oxidase (XOD), incorporated only into the test zone, catalyzes Hx oxidation to generate H2O2 and uric acid, which decompose MnO2 NFs and weaken their oxidase-like activity toward 3,3',5,5'-tetramethylbenzidine, producing an Hx-dependent color decrease. Meanwhile, the XOD-free reference zone provides a stable internal-reference signal. Ratiometric analysis (IT/IR) effectively compensates for imaging variations across different smartphones, enabling reliable visual quantification. The μPAD achieved a detection limit of 3.42 μM and agreed well with triple-quadrupole liquid chromatography-tandem mass spectrometry. Freshness monitoring of crucian carp, shrimp, and scallop was successfully demonstrated through both extract-based and direct-contact assays. This dual error-control strategy establishes a general framework for robust quantitative paper-based colorimetric sensing.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Geometry-driven miniaturization of a microfluidic paper-based analytical device for reagent-efficient colorimetric detection of dopamine.Biomedical microdevices · 2026
- Smartphone-based flow-controlled μPAD for automated nitrite determination.Lab on a chip · 2026
- A 3D Microfluidic Paper-Based Analytical Device with Smartphone-Based Colorimetric Readout for Phosphate SensingSensors · 2026
- A Laminated Microfluidic Paper-Based Analytical Device Based on Image Analysis Using Optimized Color Space for Simultaneous Multiplexed Quantification of Chemical Water Quality Parameters.Analytical chemistry · 2026
- A Metal–Organic Gel Actualized Microfluidic-Paper Analysis Device for Detecting Multiple Blood Biomarkers of Metabolic Diseases in Point-of-Care TestingAnalytical Chemistry · 2026
- Integrated Capillary-Flow-Driven Paper-Based Microfluidic Sensor and ChromaSense Lab Mobile Analytical Platform for Quantitative Detection of 6PPD in Stormwater Runoff.Analytical chemistry · 2026