Barcode-based paper analytical device for point-of-care chloride detection with user-independent readout.
Shuma Kinugasa, Yanawut Manmana, Yuki Hiruta, Daniel Citterio
Department of Applied Chemistry, Faculty of Science and Technology, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama 223-8522, Japan. citterio@applc.keio.ac.jp. · Department of Chemistry, Faculty of Science, King Mongkut's University of Technology, Thonburi Bangkok 10140, Thailand.
Key points
From the paper's conclusion- The device enabled semi-quantitative chloride determination at six concentration levels in the range of 0-200 mM through only 7 min of sample dipping and smartphone-based barcode readout.
Abstract
Microfluidic paper-based analytical devices (µPADs) have attracted considerable attention for point-of-care testing (POCT) owing to their simplicity and low cost. However, µPADs relying on visual interpretation of analytical results often lead to user-dependent measurement discrepancies and require manual recording of analytical information. To address these limitations, a barcode-based analytical device for POCT applications with smartphone-readable results has been developed. The device enabled semi-quantitative chloride determination at six concentration levels in the range of 0-200 mM through only 7 min of sample dipping and smartphone-based barcode readout. Chloride detection was achieved using a precipitation reaction-based distance-type PAD, in which the colour-changed distance was converted into barcode signals by an overlaid barcode layer to enable semi-quantitative analysis. The device provided consistent barcode readout across multiple users and smartphone models and responded selectively to chloride without interference from major urinary constituents. Furthermore, successful semi-quantitative analysis of chloride was achieved in undiluted human urine samples, demonstrating the applicability of the device to real samples. Analysis of chloride in undiluted human saliva was also demonstrated, while requiring a longer assay time that may be related to the higher viscosity of saliva. The developed device provides a promising platform for POCT and has the potential to be extended to semi-quantitative analysis of analytes beyond chloride.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A barcode-enabled distance-based paper sensor using silver chloranilate for semi-quantitative determination of chloride in various water sources.Analytical methods : advancing methods and applications · 2026
- A Laminated Microfluidic Paper-Based Analytical Device Based on Image Analysis Using Optimized Color Space for Simultaneous Multiplexed Quantification of Chemical Water Quality Parameters.Analytical chemistry · 2026
- A 3D Microfluidic Paper-Based Analytical Device with Smartphone-Based Colorimetric Readout for Phosphate SensingSensors · 2026
- Microfluidic Paper-Based Devices at the Edge of Real Samples: Fabrication Limits, Hybrid Detection, and PerspectivesMicromachines · 2026
- Progress toward real-world diagnostic applications of microfluidic paper-based analytical devices (μPADs)Lab on a Chip · 2026
- Development of a microfluidic paper-based analytical device (μPAD) for detection of urea, nitrite, and starch adulteration in milk with smartphone app assisted detectionInnovative Food Science & Emerging Technologies · 2026