Analytical methods : advancing methods and applications

Long ssDNA probe catalytic hairpin assembly cascade reaction based AuNPs aggregation assay for sensitive and colorimetric analysis of anesthesia-induced delirium related microRNA.

Mingzhen Li, Baojun Zhang

Department of Anesthesiology and Perioperative Medicine, Xinxiang Central Hospital (The Fourth Clinical College of Henan Medical University), No. 56, Jinsui Avenue, Weibin District, Xinxiang City, 453000, Henan Province, China. 466542552@qq.com.

Key points

From the paper's conclusion
  • This platform offers several compelling advantages: (i) the CHA cascade ensures robust signal amplification with a detection limit as low as 3.5 fM; (ii) the solid-phase scaffold enables efficient washing to suppress background interference; (iii) the assay exhibits exceptional specificity capable of discriminating single-base mismatches; and (iv) the colorimetric readout is instrument-free and us

Abstract

Anesthesia-induced delirium (AID) is a severe postoperative complication lacking objective molecular diagnostic tools, underscoring an urgent need for sensitive and point-of-care analytical methods. Herein, we report a novel colorimetric biosensing strategy for AID-related microRNA detection based on a long single-stranded DNA (ssDNA) probe-mediated catalytic hairpin assembly (CHA) cascade coupled with gold nanoparticles (AuNPs) aggregation. In this design, a long ssDNA scaffold harboring repeated hairpin functional domains is fabricated via rolling circle amplification on a solid-phase plate. Upon target miRNA recognition, the CHA cascade is initiated among three AuNP-labeled hairpin probes, which are subsequently assembled onto the scaffold in a highly ordered manner, dramatically reducing inter-particle distances and triggering a distinct absorbance change. This platform offers several compelling advantages: (i) the CHA cascade ensures robust signal amplification with a detection limit as low as 3.5 fM; (ii) the solid-phase scaffold enables efficient washing to suppress background interference; (iii) the assay exhibits exceptional specificity capable of discriminating single-base mismatches; and (iv) the colorimetric readout is instrument-free and user-friendly. Furthermore, spike-and-recovery tests yielded recoveries of 96.5-101.2%, and the system maintained excellent stability over 7 days at 4 °C. Clinical application to serum samples from AID patients demonstrated significantly elevated target miRNA levels and an excellent correlation with RT-qPCR. This work presents a robust, sensitive, and practical diagnostic tool for AID-related miRNA detection, holding great promise for early screening and personalized perioperative neurological risk assessment.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers