Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy

Intramolecular catalytic hairpin assembly on a DNA triangular prism for sensitive imaging of apoptosis-related mRNA in living cells.

Chun Tian, Hua Rong Lin, Lin He, Jing Li, Xiao Qiao Wu, Shan Shan Huang, Cheng Zhi Huang, Yong Peng He,

Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Pharmaceutical Sciences, Southwest University, Chongqing 400715, PR China. · Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Pharmaceutical Sciences, Southwest University, Chongqing 400715, PR China; Department of Pharmacy, Neijiang Health Vocational College, Sichuan 641100, PR China.

Key points

From the paper's conclusion
  • In summary, this intra-CHA3 probe provides a versatile tool for live-cell mRNA imaging and holds significant potential for advancing cancer diagnosis and elucidating apoptosis-related mechanisms.

Abstract

Accurate analysis of mRNA in living cells holds great promise for early diagnosis of cancer and the comprehension of apoptosis. However, detection of apoptosis-related mRNAs by current approaches still faces challenges, including insufficient sensitivity, poor stability, and the difficulty of achieving real-time dynamic monitoring in living cells. Herein, we proposed a DNA triangular prism (DTP)-based probe that loads three pairs of identical hairpin reactants on one nanocarrier (intra-CHA3 probe), thus enabling high-loaded target-induced intramolecular catalytic hairpin assembly. The confinement effect of reactants and framework nucleic acid-based nanocarrier endows this probe with high sensitivity and excellent nuclease stability, respectively, which is beneficial for the sensitive detection of low-abundance targets, especially in live cell biosensing. The intra-CHA3 probe was successfully applied for the detection of MnSOD mRNA with a linear range of 0.05-10 nmol/L and a detection limit of 30 pmol/L. Furthermore, it enabled imaging of MnSOD mRNA expression in different cell lines, revealing distinct probe-derived fluorescence responses among the examined cancer-derived and normal cell lines. Furthermore, the probe was employed for real-time monitoring of dynamic MnSOD mRNA level changes during apoptosis in cancer cells. In summary, this intra-CHA3 probe provides a versatile tool for live-cell mRNA imaging and holds significant potential for advancing cancer diagnosis and elucidating apoptosis-related mechanisms.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers