Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy

A single-probe isothermal amplification platform for point-of-care detection of circulating microRNAs in ophthalmic and oncological diseases.

Haijian Wu, Xiaobei Lyu, Weilin Lu, Zhiwei Xu, Huo Xu

Taizhou Municipal Hospital (Taizhou University Affiliated Municipal Hospital), School of Medicine, Taizhou University, Zhejiang, China. · Taizhou Municipal Hospital (Taizhou University Affiliated Municipal Hospital), School of Medicine, Taizhou University, Zhejiang, China. Electronic address: xuzhiwei@zju.edu.cn.

Key points

From the paper's conclusion
  • The clinical demand for point-of-care (POC) detection of ophthalmic biomarkers, such as microRNA-21 (miR-21) for diabetic retinopathy (DR), is hampered by current assays that are often time-consuming, operationally complex, or prone to high background noise.

Abstract

The clinical demand for point-of-care (POC) detection of ophthalmic biomarkers, such as microRNA-21 (miR-21) for diabetic retinopathy (DR), is hampered by current assays that are often time-consuming, operationally complex, or prone to high background noise. To address this, we developed an ACH-based One-step Isothermal Instantaneous Cascade Amplification (ACH-OIICA) strategy. This platform relies on a single Autonomous Catalytic Hairpin (ACH) functioning as an "all-in-one" DNA nanomachine, which integrates target recognition, cascade amplification templating, and signal reporting, thereby eliminating the need for exogenous primers. Upon binding to miR-21, the ACH undergoes a conformational change that triggers a self-sustained cycle of polymerization and nicking, rapidly generating abundant G-quadruplex DNAzymes. The assay achieves a detection limit of 15.6 pM with a naked-eye distinguishable colorimetric readout. It demonstrates single-base specificity and robust performance in complex biological matrices. Crucially, ACH-OIICA proved its broad diagnostic utility across two distinct disease cohorts: it successfully differentiated patients with colorectal cancer (CRC) from healthy controls, and accurately distinguished patients with DR from healthy controls (HC). This work offers a streamlined, rapidly initiated, and highly sensitive platform, providing a robust framework for next-generation molecular diagnostics in clinical environment.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers